Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output |
|---|---|---|---|---|---|---|
|
4ETO City Technology - Electrochemical Cell for Ethylene Oxide |
Life expectancy
> 24 months
|
Measurement range
0-20 ppm
|
Target Gas
Ethylene Oxide
|
Response Time
< 120 seconds (T90)
|
Output
1.9 ± 0.5 μA/ppm
|
|
7HL City Technology - Electrochemical Cell for Hydrogen Chloride |
Life expectancy
> 24 months
|
Measurement range
0-50 ppm
|
Target Gas
Hydrogen Chloride
|
Response Time
< 120 seconds (T90)
|
Output
750 ± 250 nA/ppm
|
|
A02 Electrochemical cell for oxygen, range 0-100%, indicated for gas analyzer for automotive and for food storage applications. |
Life expectancy
> 24 months
|
Measurement range
0-100%
|
Target Gas
Oxygen
|
Response Time
< 5 seconds (T90)
|
Output
9 - 13 mV in air
|
|
A03 Electrochemical cell for oxygen, range 0-100%, indicated for gas analyzer for automotive and food storage applications. |
Life expectancy
> 24 months
|
Measurement range
0-100%
|
Target Gas
Oxygen
|
Response Time
< 5 seconds (T90)
|
Output
9 - 13 mV in air
|
|
|
AOX |
Life expectancy
About 2 years in air
|
Target Gas
Oxygen
|
Response Time
<5 seconds (T90)
|
Output
9 - 13 mV in air
|
|
|
AQ3ND City Technology - Electrochemical cell for Nitrogen Dioxide Air Quality cell |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 120 seconds (T90)
|
Output
1.029 ± 0.294 mV/ppb
|
|
AQ3OZ City Technology - Electrochemical cell for Ozone |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Ozone
|
Response Time
< 120 seconds (T90)
|
Output
1.20 ± 0.50 mV/ppb
|
|
AQ7ND |
Life expectancy
> 24 months
|
Measurement range
0 ppm NO2 to 1 ppm NO2
|
Target Gas
Nitrogen dioxide
|
Response Time
< 120 seconds (T90)
|
|
|
AQ7OZ |
Life expectancy
> 24 months
|
Measurement range
0 ppm O3 to 1 ppm O3
|
Target Gas
Ozone
|
Response Time
< 120 seconds (T90)
|
|
|
COCl2 3E 1 City Technology - Electrochemical Cell for Phosgene |
Life expectancy
> 12 months
|
Measurement range
0-1 ppm
|
Target Gas
Phosgene
|
Response Time
< 120 seconds (T90)
|
Output
650 ± 150 nA/ppm
|