Gas sensors
Gas sensors
| Product | Description | Application field | Target Gas | Heater consumption | Measurement range | Accuracy | Energetic consumption | Output current | Reading per seconds | Temperature range | Response Time | Output | Life expectancy |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TGS6810-D00 The TGS6810-D00 catalytic type gas sensor can detect both methane and LP gas and it has been developed for residential gas detection. |
Application field
Domestic
|
Target Gas
LPG
Methane
|
||||||||||
|
TGS6812-D00 The catalytic sensor TGS6812-D00 can detect hydrogen levels up to 100% LEL. |
Target Gas
Hydrogen
Methane
Propane
Isobutane
|
Heater consumption
525 mW typical
|
Measurement range
0-100% LEL of each gas
|
|||||||||
|
ULTRA.sens® AK100 H2S The ULTRA.sens® is the world’s first OEM gas measurement module based on miniaturized UV LEDs. The stability and lifetime of these UV-LEDs enables high-precision gas analyses down to the ppb range. |
Target Gas
Multigas
|
Measurement range
<100 Vol.%
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Output current
RS232, Can, Analogic
|
Reading per seconds
3 seconds (T90)
|
Temperature range
5°C – 45°C
|
|||||
|
ULTRA.sens® AK100 TBH The ULTRA.sens® is the world’s first OEM gas measurement module based on miniaturized UV LEDs. The stability and lifetime of these UV-LEDs enables high-precision gas analyses down to the ppb range. |
Target Gas
Multigas
|
Measurement range
<100 Vol.%
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Output current
RS232, Can, Analogic
|
Reading per seconds
3 seconds (T90)
|
Temperature range
5°C – 45°C
|
|||||
|
ULTRA.sens® AK100 TBH (UVRAS) The ULTRA.sens® is the world’s first OEM gas measurement module based on miniaturized UV LEDs. The stability and lifetime of these UV-LEDs enables high-precision gas analyses down to the ppb range. |
Target Gas
Multigas
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Output current
RS232, Can, Analogic
|
Reading per seconds
3 seconds (T90)
|
Temperature range
5°C – 45°C
|
||||||
|
Ultra.Sens AK100 The ULTRA.sens® is the world’s first OEM gas measurement module based on miniaturized UV LEDs. The stability and lifetime of these UV-LEDs enables high-precision gas analyses down to the ppb range. |
Target Gas
Multigas
|
Measurement range
< 1 Vol.%
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 3 Watt @ 24 VDC
|
Temperature range
5°C – 45°C
|
Response Time
1 second (T90)
|
Output
RS232, Can, Analog
|
|||||
|
Ultra.Sens AK25 The ULTRA.sens® is the world’s first OEM gas measurement module based on miniaturized UV LEDs. The stability and lifetime of these UV-LEDs enables high-precision gas analyses down to the ppb range. |
Target Gas
Multigas
|
Measurement range
< 10 Vol.%
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 3 Watt @ 24 VDC
|
Temperature range
5°C – 45°C
|
Response Time
1 second (T90)
|
Output
RS232, Can, Analog
|
|||||
|
Ultra.Sens AK250 The ULTRA.sens® is the world’s first OEM gas measurement module based on miniaturized UV LEDs. The stability and lifetime of these UV-LEDs enables high-precision gas analyses down to the ppb range. |
Target Gas
Multigas
|
Measurement range
< 1000ppm
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 3 Watt @ 24 VDC
|
Temperature range
5°C – 45°C
|
Response Time
1 second (T90)
|
Output
RS232, Can, Analog
|
|||||
|
Ultra.Sens AK550 The ULTRA.sens® is the world’s first OEM gas measurement module based on miniaturized UV LEDs. The stability and lifetime of these UV-LEDs enables high-precision gas analyses down to the ppb range. |
Target Gas
Multigas
|
Measurement range
< 250ppm
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 3 Watt @ 24 VDC
|
Temperature range
5°C – 45°C
|
Response Time
1 second (T90)
|
Output
RS232, Can, Analog
|
|||||
|
iseries iCO |
Target Gas
Carbon Monoxide
|
Measurement range
0.5 ppm CO to 1000 ppm
|
Response Time
< 20 seconds (T90)
|
Output
UART
|
Life expectancy
5 years
|