| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Working temperature | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3SH City Technology - 3 Electrode Electrochemical Cell for Sulfur dioxide |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Sulphur dioxide
|
Response Time
< 15 seconds (T90)
|
Output
1.25 ± 0.25 μA/ppm
|
||||||
|
4ND City Technology - Electrochemical Cell for Nitrogen Dioxide NO2 |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 25 seconds (T90)
|
Output
600 ± 150 nA/ppm
|
||||||
|
GS+4ETO Electrochemical cell for ethylene oxide, ideal for many applications like fruit ripening. |
Life expectancy
> 2 years in air
|
Measurement range
0 - 20 ppm
|
Target Gas
Ethylene Oxide
|
Response Time
< 120 seconds (T90)
|
Output
1.9 ± 0.6 μA/ppm
|
||||||
|
GS+4SO2 Electrochemical cell for sulphur dioxide, ideal for portable and fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Sulphur dioxide
|
Response Time
< 30 seconds (T90)
|
Output
500 ± 100 nA/ppm
|
||||||
|
GS+7CL2 Electrochemical cell for chlorine, ideal for fixed gas detectors. |
Life expectancy
> 12 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Chlorine
|
Response Time
< 60 seconds (T90)
|
Output
1.0 ± 0.3 μA/ppm
|
||||||
|
GS+7ETO Electrochemical cell for ethylene oxide, ideal for many fixed instrument applications. |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Ethylene Oxide
|
Response Time
< 120 seconds (T90)
|
Output
2.5 ± 0.7 μA/ppm
|
||||||
|
S+42NO2 Electrochemical cell for nitrogen dioxide, ideal for car park and ventilation systems. |
Life expectancy
> 2 years in air
|
Measurement range
0 - 20 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 60 seconds (T90)
|
Output
300 ± 100 nA/ppm
|
||||||
|
T-110 As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-10%
0.04-5%
0.04-3%
0.04-2%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19 x 29.3 x 8.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Working temperature
0°C / 50°C
|
|||
|
T-110-3V As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application. |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0-2%
0-3%
0-5%
0-10%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
19 x 29.3 x 8.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
0°C / +50°C
|
|||
|
T-200 NDIR module for CO2 measurement |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
UART
Analogica (0.5V - 4.5V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19.4 x 30 x10.3 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature