Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature | Energetic consumption | Temperature range |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
GS+4NO2 Electrochemical cell for nitrogen dioxide, ideal for portable and fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0 – 30 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 30 seconds (T90)
|
Output
600 ± 150 nA/ppm
|
|||||||
|
H-250-12V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
PWM
I2C
UART
Analog (0.5V - 4.5V)
|
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
50 x 69 x 20 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
||||
|
H-250-3V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
||||
|
H-250-5V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 4.5V)
|
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
||||
|
HCN 2E 30 F City Technology - Electrochemical Cell for Hydrogen cyanide HCN |
Life expectancy
> 18 months
|
Measurement range
0 – 30 ppm
|
Target Gas
Hydrogen cyanide
|
Response Time
< 30 seconds (T90)
|
Output
30 ± 15 nA/ppm
|
|||||||
|
HCN 3E 30 F City Technology - Electrochemical Cell Hydrogen cyanide HCN 3 Electrode sensor with organic electrolyte. |
Life expectancy
> 18 months
|
Measurement range
0 – 30 ppm
|
Target Gas
Hydrogen cyanide
|
Response Time
< 50 seconds (T90)
|
Output
60 ± 15 nA/ppm
|
|||||||
|
Ultra.Sens AK250 The ULTRA.sens® is the world’s first OEM gas measurement module based on miniaturized UV LEDs. The stability and lifetime of these UV-LEDs enables high-precision gas analyses down to the ppb range. |
Measurement range
< 1000ppm
|
Target Gas
Multigas
|
Response Time
1 second (T90)
|
Output
RS232, Can, Analog
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 3 Watt @ 24 VDC
|
Temperature range
5°C – 45°C
|
|||||
|
Discontinued
|
H2S-2E-30 City Technology (Sensoric) - 2 Electrode sensor with organic electrolyte for Hydrogen sulfide (AsH3) |
Life expectancy
> 18 months
|
Measurement range
0 – 30 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
60 ± 30 nA/ppm
|