Gas sensors
Gas sensors
| Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Operating temperature | Output |
|---|---|---|---|---|---|---|---|---|---|
|
CH4-LD-3V NDIR module for the measure of CH4 |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-5000 ppm
0-50000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Methane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
Analog (0.5V - 3.0V)
UART
|
|
CH4-LF-3V NDIR module for the measure of CH4 |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-5000 ppm
0-50000 ppm
|
Humidity range
0-99% RH
0-95% RH
|
Target Gas
Methane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|