Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Working temperature | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3CLH City Technology - Electrochemical Cell for Chlorine |
Life expectancy
> 24 months
|
Measurement range
0-20 ppm
|
Target Gas
Chlorine
|
Response Time
< 60 seconds (T80)
|
Output
1 ± 0.25 μA/ppm
|
||||||
|
3ETO City Technology - Electrochemical Cell for Ethylene Oxide |
Life expectancy
> 24 months
|
Measurement range
0-20 ppm
|
Target Gas
Ethylene Oxide
|
Response Time
< 140 seconds (T90)
|
Output
2.75 ± 0.5 μA/ppm
|
||||||
|
3NDH City Technology - electrochemical cell for Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-20 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 40 seconds (T90)
|
Output
1.4 ± 0.3 μA/ppm
|
||||||
|
4ETO City Technology - Electrochemical Cell for Ethylene Oxide |
Life expectancy
> 24 months
|
Measurement range
0-20 ppm
|
Target Gas
Ethylene Oxide
|
Response Time
< 120 seconds (T90)
|
Output
1.9 ± 0.5 μA/ppm
|
||||||
|
7ETO City Technology - Electrochemical Cell for Ethylene Oxide |
Life expectancy
> 24 months
|
Measurement range
0-20 ppm
|
Target Gas
Ethylene Oxide
|
Response Time
< 140 seconds (T90)
|
Output
2.25 ± 0.65 μA/ppm
|
||||||
|
7NDH City Technology - electrochemical cell for Nitrogen Dioxide |
Life expectancy
24 months
|
Measurement range
0-20 ppm
|
Target Gas
Nitrogen Dioxide
|
Response Time
< 40 seconds (T90)
|
Output
1.4 ± 0.3 μA/ppm
|
||||||
|
7SH City Technology - electrocheical cell for Sulfur Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-20 ppm
|
Target Gas
Sulfur Dioxide
|
Response Time
< 15 seconds (T90)
|
Output
1.25 ± 0.25 μA/ppm
|
||||||
|
T-110 As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-10%
0.04-5%
0.04-3%
0.04-2%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19 x 29.3 x 8.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Working temperature
0°C / 50°C
|
|||
|
T-200 NDIR module for CO2 measurement |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
UART
Analogica (0.5V - 4.5V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19.4 x 30 x10.3 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +60°C
|
|||
|
T-200-3V NDIR module for CO2 measurement. |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
19.4 x 30 x10.3 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +60°C
|