Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
3ND City Technology - Electrochemical Cell for Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 35 seconds (T90)
|
Output
370 ± 70 nA/ppm
|
|||||
|
3NDH City Technology - electrochemical cell for Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-20 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 40 seconds (T90)
|
Output
1.4 ± 0.3 μA/ppm
|
|||||
|
4ND City Technology - Electrochemical Cell for Nitrogen Dioxide NO2 |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 25 seconds (T90)
|
Output
600 ± 150 nA/ppm
|
|||||
|
5ND City Technology - Electrochemical Cell for Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-200 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 60 seconds (T90)
|
Output
370 ± 70 nA/ppm
|
|||||
|
A3OZ City Technology 4 Electrode environmental monitoring sensor for Ozone and Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-10 ppm
|
Target Gas
Ozone
Nitrogen dioxide
|
Response Time
< 40 seconds (T90)
|
Output
2.2 ± 0.5 μA/ppm
|
|||||
|
AQ3ND City Technology - Electrochemical cell for Nitrogen Dioxide Air Quality cell |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 120 seconds (T90)
|
Output
1.029 ± 0.294 mV/ppb
|
|||||
|
AQ7ND |
Life expectancy
> 24 months
|
Measurement range
0 ppm NO2 to 1 ppm NO2
|
Target Gas
Nitrogen dioxide
|
Response Time
< 120 seconds (T90)
|
||||||
|
C4H10-S3-3V NDIR module for the measure of Butane. |
Measurement range
0-100% LEL
0-18000 ppm
|
Target Gas
Butano
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 2% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
GS+4NO2 Electrochemical cell for nitrogen dioxide, ideal for portable and fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0 – 30 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 30 seconds (T90)
|
Output
600 ± 150 nA/ppm
|
|||||
|
LPM2610-C13 The LPM2610 is a pre-calibrated module for LP gas alarms which is precisely calibrated in Figaro’s humidity and temperature controlled facility. The module uses TGS2610-C00. |
Target Gas
LPG
|