Gas sensors
Gas sensors
| Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Operating temperature | Output | Current Consumption (mA) |
|---|---|---|---|---|---|---|---|---|---|---|
|
C2H4-CD300 Transmitter board with NDIR sensor for Ethylene (C2H4) |
Accuracy
± 3% F.S.
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-100% LEL
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Ethylene
|
Operating temperature
-20°C / +50°C
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
|
|
C2H4-D3 NDIR module for the measure of Ethylene (C2H4) |
Accuracy
± 3% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Ethylene
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
|
|
C2H4-D3-3V NDIR module for the measure of Ethylene (C2H4) |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Ethylene
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
|
|
C2H4-LD-3V NDIR module for the measure of Ethylene |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-2000 ppm
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Ethylene
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
|
|
C2H4-LF-3V NDIR module for the measure of Ethylene. |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-2000 ppm
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Ethylene
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
|
|
C2H4-S3 NDIR module for the measure of Ethylene |
Accuracy
± 3% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-100% LEL
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Ethylene
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
PWM
Analog (0.5V - 4.5V)
|
|
|
C2H4-S3-3V NDIR module for the measure of Ethylene |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-100% LEL
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Ethylene
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
PWM
Analog (0.5V - 3.0V)
|
|
|
NEXT-PM Module for PM10/2.5/1.0 measurement based on proprietary Laser technology. UART output or RS485. |
Power Supply
5.0 Vdc
|
Measurement range
0-1000 ㎍/㎥
|
Target Gas
PM2.5 / PM1.0
PM10
|
Output
UART
RS485
|
Current Consumption (mA)
250 mA
|
||||
|
NEXT-PM Lite Compact size measurement module for particulate matter PM10/2.5/1.0 based on proprietary Laser technology |
Power Supply
5.0 Vdc
|
Measurement range
0-1000 ㎍/㎥
|
Target Gas
PM2.5 / PM1.0
PM10
|
Output
UART
RS485
|
Current Consumption (mA)
<50 mA
|
||||
|
PSML Infrared module for PM2.5/1.0 measurement based on proprietary IrED technology. UART LPO (Low Pulse Occupancy) |
Power Supply
5.0 Vdc
|
Measurement range
0-500 ㎍/㎥
|
Target Gas
PM2.5 / PM1.0
|
Output
LPO (Low Pulse Occupancy)
|