| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output |
|---|---|---|---|---|---|---|
|
4OX ECO LP City Technology - Electrochemical Cell for Oxygen |
Life expectancy
> 5 years
|
Measurement range
0-25% Oxygen
|
Target Gas
Oxygen
|
Response Time
< 15 seconds (T90)
|
Output
80 - 130 μA in air
|
|
HCN 3E 30 F City Technology - Electrochemical Cell Hydrogen cyanide HCN 3 Electrode sensor with organic electrolyte. |
Life expectancy
> 18 months
|
Measurement range
0 – 30 ppm
|
Target Gas
Hydrogen cyanide
|
Response Time
< 50 seconds (T90)
|
Output
60 ± 15 nA/ppm
|