| Product | Description | Power Supply | Measurement range | Target Gas | Output | Accuracy | Energetic consumption | Temperature range | Response Time | Output formats | Temp. drift | Compatible sensors |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FCX-MEP2-F This board allows to measure the oxygen concentration in range 0.1-25%. |
Power Supply
12 +/- 3 VDC
|
Measurement range
0,1-25%
|
Target Gas
Oxygen
|
Output
4-20 mA not linear
|
|||||||
|
FCX-MQ-F-AC This board allows to measure the oxygen concentration in range 0.05-1%. |
Power Supply
5 +/- 0,2 VDC
|
Measurement range
0,05-1%
|
Target Gas
Oxygen
|
Output
50-1000 mV not linear
|
|||||||
|
FCX-MVL-F This board allows to measure the oxygen concentration in range 0.1-25% |
Power Supply
5 +/- 0,2 VDC
|
Measurement range
0,1-25%
|
Target Gas
Oxygen
|
Output
1-250 mV linear
|
|||||||
|
FCX-MWL-F This board allows to measure the oxygen concentration in range 0.1-95% |
Power Supply
5 +/- 0,2 VDC
|
Measurement range
0,1-95%
|
Target Gas
Oxygen
|
Output
1-950 mV linear
|
|||||||
|
HUMI.sens Humidity sensor Humidity sensor | |||||||||||
|
INFRA.sens® AK2 SF6 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
<1 Vol.%
|
Target Gas
Multigas
|
Output
RS232, Can, Analogic
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 seconds (T90)
|
||||
|
INFRA.sens® AK20 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
<1 Vol.%
|
Target Gas
Multigas
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Output formats
RS232, Can, Analogica
|
Temp. drift
3 secondi (T90)
|
||||
|
INFRA.sens® AK250TBH The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
<100 Vol.%
|
Target Gas
Multigas
|
Output
RS232, Can, Analogica
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 secondi (T90)
|
||||
|
INLINE Safety Filter Safety filter |
Compatible sensors
Gas Analyzer Equipment
|
||||||||||
|
Infra.Sens AK100 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
< 1 Vol.%
|
Target Gas
Multigas
|
Output
RS232, Can, Analog
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 seconds (T90)
|