Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Compatible sensors |
|---|---|---|---|---|---|---|---|
|
3HYE City Technology - 3 Electrode Electrochemical Cell for Hydrogen |
Life expectancy
> 24 months
|
Measurement range
0-10.000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 70 seconds (T90)
|
Output
3 ± 1 nA/ppm
|
|
|
3SH City Technology - 3 Electrode Electrochemical Cell for Sulfur dioxide |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Sulphur dioxide
|
Response Time
< 15 seconds (T90)
|
Output
1.25 ± 0.25 μA/ppm
|
|
|
4ND City Technology - Electrochemical Cell for Nitrogen Dioxide NO2 |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 25 seconds (T90)
|
Output
600 ± 150 nA/ppm
|
|
|
7HYE City Technology - Electrochemical Cell for Hydrogen |
Life expectancy
> 24 months
|
Measurement range
0-10.000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 110 seconds (T90)
|
Output
3 ± 1 nA/ppm
|
|
|
A5F+ City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
60 ± 20 nA/ppm
|
|
|
A5F+ City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
60 ± 20 nA/ppm
|
|
|
EM5042A Evaluation module for the CO sensor TGS5042 |
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|
Compatible sensors
TGS5042
|
|||
|
GS+4COHC Electrochemical cell for carbon monoxide, indicated for high concentration applications. |
Life expectancy
> 2 years in air
|
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 40 seconds (T90)
|
Output
20 ± 10 nA/ppm
|
|
|
GS+4ETO Electrochemical cell for ethylene oxide, ideal for many applications like fruit ripening. |
Life expectancy
> 2 years in air
|
Measurement range
0 - 20 ppm
|
Target Gas
Ethylene Oxide
|
Response Time
< 120 seconds (T90)
|
Output
1.9 ± 0.6 μA/ppm
|
|
|
GS+4SO2 Electrochemical cell for sulphur dioxide, ideal for portable and fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Sulphur dioxide
|
Response Time
< 30 seconds (T90)
|
Output
500 ± 100 nA/ppm
|