Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
A3OZ City Technology 4 Electrode environmental monitoring sensor for Ozone and Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-10 ppm
|
Target Gas
Ozone
Nitrogen dioxide
|
Response Time
< 40 seconds (T90)
|
Output
2.2 ± 0.5 μA/ppm
|
|||||
|
A3STF City Technology - Electrochemical Cell for Sulfur Dioxide |
Life expectancy
> 3 years
|
Measurement range
0-10 ppm
|
Target Gas
Sulfur Dioxide
|
Response Time
< 40 seconds (T90)
|
Output
600 ± 120 nA/ppm
|
|||||
|
AQ3CO City Technology - Electrochemical cell for Carbon Monoxide Air Quality cell |
Life expectancy
> 24 months
|
Measurement range
0-10 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 60 seconds (T90)
|
Output
0.0726 ± 0.0145mV/ppb
|
|||||
|
C3H8-CD300 Transmitter board with NDIR sensor for Propane (C3H8) |
Measurement range
0-100% LEL
0-21000 ppm
|
Target Gas
Propane
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
Accuracy
± 3% F.S.
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
C3H8-D3 NDIR module for the measure of Propane (C3H8) |
Measurement range
0-21000 ppm
|
Target Gas
Propane
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Accuracy
± 3% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-99% RH
0-95% RH
|
Operating temperature
-20°C / +50°C
|
||
|
C3H8-D3-3V NDIR module for the measure of Propane (C3H8) |
Measurement range
0-21000 ppm
|
Target Gas
Propane
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
C3H8-LD-3V NDIR module for the measure of Propane |
Measurement range
0-5000 ppm
0-21000 ppm
|
Target Gas
Propane
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
C3H8-LF-3V NDIR module for the measure of Propane. |
Measurement range
0-5000 ppm
0-21000 ppm
|
Target Gas
Propane
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
C3H8-S3 NDIR module for the measure of Propane. |
Measurement range
0-100% LEL
0-21000 ppm
|
Target Gas
Propane
|
Output
I2C
PWM
Analog (0.5V - 4.5V)
UART
|
Accuracy
± 3% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
C3H8-S3-3V NDIR module for the measure of Propane. |
Measurement range
0-100% LEL
0-21000 ppm
|
Target Gas
Propane
|
Output
I2C
PWM
Analog (0.5V - 3.0V)
UART
|
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|