Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Compatible sensors | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3HYE City Technology - 3 Electrode Electrochemical Cell for Hydrogen |
Life expectancy
> 24 months
|
Measurement range
0-10.000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 70 seconds (T90)
|
Output
3 ± 1 nA/ppm
|
||||||
|
7HYE City Technology - Electrochemical Cell for Hydrogen |
Life expectancy
> 24 months
|
Measurement range
0-10.000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 110 seconds (T90)
|
Output
3 ± 1 nA/ppm
|
||||||
|
A5F+ City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
60 ± 20 nA/ppm
|
||||||
|
A5F+ City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
60 ± 20 nA/ppm
|
||||||
|
EM5042A Evaluation module for the CO sensor TGS5042 |
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|
Compatible sensors
TGS5042
|
||||||||
|
GS+4COHC Electrochemical cell for carbon monoxide, indicated for high concentration applications. |
Life expectancy
> 2 years in air
|
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 40 seconds (T90)
|
Output
20 ± 10 nA/ppm
|
||||||
|
H-250-12V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
PWM
I2C
UART
Analog (0.5V - 4.5V)
|
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
50 x 69 x 20 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
|||
|
H-250-3V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
|||
|
H-250-5V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 4.5V)
|
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
|||
|
H2 3E 1% City Technology - Electrochemical Cell for Hydrogen |
Life expectancy
> 24 months
|
Measurement range
0-10.000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 70 seconds (T90)
|
Output
10 ± 5 nA/ppm
|