Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Power Supply |
|---|---|---|---|---|---|---|---|
|
MOX-1 City Technology - Electrochemical Cell for Oxygen O2 |
Life expectancy
1.5 x 106 % O2 hours at 20°C
|
Measurement range
0-1500 mBar O2
|
Target Gas
Oxygen
|
Response Time
< 15 seconds (T90)
|
Output
9 - 13 mV in 210 mBar O2
|
|
|
Discontinued
|
CDM7160-C00 Pre-calibrated CO2 module uses a compact NDIR CO2 sensor. |
Measurement range
300-5000 ppm CO2
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
|
Power Supply
4.5-5.25 VDC
|