| Product | Description | Power Supply | Measurement range | Target Gas | Output | Accuracy | Dimension | Humidity range | Working temperature | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|
|
EDI030104NG The Gascard NG is a OEM board with infrared sensor for the measuring of CO2. |
Power Supply
24V DC (7-30V)
|
Measurement range
0-1%
|
Target Gas
Carbon dioxide
|
Output
0-20 mA
|
|||||
|
EDI030206NG The Gascard NG is a OEM board with infrared sensor for the measuring of CH4. |
Power Supply
24V DC (7-30V)
|
Measurement range
0-1%
|
Target Gas
Methane
|
Output
0-20 mA
4-20 mA
|
|||||
|
EDI080111NG Guardian NG is a stand-alone analyzer for CO2, with infrared sensor technology. |
Power Supply
from 90 to 260 VAC
|
Measurement range
0-1%
|
Target Gas
Carbon dioxide
|
Output
0-20 mA
4-20 mA
|
|||||
|
EDI080111NGDC Guardian NG is a stand-alone analyzer for CO2, with infrared sensor technology. |
Power Supply
24V DC (18-30 V DC)
|
Measurement range
0-1%
|
Target Gas
Carbon dioxide
|
Output
4-20 mA
0-20 mA
|
|||||
|
EDI080201NG Guardian NG is a stand-alone analyzer for CH4, with infrared sensor technology. |
Power Supply
from 90 to 260 VAC
|
Measurement range
0-1%
|
Target Gas
Methane
|
Output
0-20 mA
4-20 mA
|
|||||
|
EDI080301NGDC Guardian NG is a stand-alone analyzer for CH4, with infrared sensor technology. |
Power Supply
24V DC (7-30V)
|
Measurement range
0-1%
|
Target Gas
Methane
|
Output
0-20 mA
4-20 mA
|
|||||
|
T-110 As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application |
Power Supply
5.0 Vdc
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-10%
0.04-5%
0.04-3%
0.04-2%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
19 x 29.3 x 8.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Working temperature
0°C / 50°C
|
|
|
T-110-3V As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application. |
Power Supply
3.3 Vdc
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0-2%
0-3%
0-5%
0-10%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
19 x 29.3 x 8.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
0°C / +50°C
|
|
|
T-200 NDIR module for CO2 measurement |
Power Supply
5.0 Vdc
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
UART
Analogica (0.5V - 4.5V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
19.4 x 30 x10.3 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +60°C
|
|
|
T-200-3V NDIR module for CO2 measurement. |
Power Supply
3.3 Vdc
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
19.4 x 30 x10.3 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature