Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
3SH City Technology - 3 Electrode Electrochemical Cell for Sulfur dioxide |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Sulphur dioxide
|
Response Time
< 15 seconds (T90)
|
Output
1.25 ± 0.25 μA/ppm
|
|||||
|
C4H10-CD300 Transmitter board with NDIR sensor for Butane (C4H10) |
Measurement range
0-100% LEL
0-18000 ppm
|
Target Gas
Butane
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
Accuracy
± 3% F.S.
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
C4H10-D3 NDIR module for the measure of Butane (C4H10) |
Measurement range
0-18000 ppm
|
Target Gas
Butane
|
Output
I2C
UART
PWM
Analog (0.5V - 4.5V)
|
Accuracy
± 3% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
C4H10-D3-3V NDIR module for the measure of Butane (C4H10) |
Measurement range
0-18000 ppm
|
Target Gas
Butane
|
Output
I2C
UART
PWM
Analog (0.5V - 3.0V)
|
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
C4H10-LD-3V NDIR module for the measure of Butane. |
Measurement range
0-5000 ppm
0-18000 ppm
|
Target Gas
Butane
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
C4H10-LF-3V NDIR module for the measure of Butane. |
Measurement range
0-5000 ppm
0-18000 ppm
|
Target Gas
Butane
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
C4H10-S3 NDIR module for the measure of Butane. |
Measurement range
0-100% LEL
0-18000 ppm
|
Target Gas
Butane
|
Output
I2C
PWM
UART
Analog (0.5V - 4.5V)
|
Accuracy
± 2% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
EZT3SF City Technology - Electrochemical Cell for Sulfur dioxide SO2 |
Life expectancy
> 24 months
|
Target Gas
Sulphur dioxide
|
Response Time
< 30 seconds (T90)
|
Output
4-20 mA
|
||||||
|
GS+4SO2 Electrochemical cell for sulphur dioxide, ideal for portable and fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Sulphur dioxide
|
Response Time
< 30 seconds (T90)
|
Output
500 ± 100 nA/ppm
|
|||||
|
GS+7SO2 Electrochemical cell for sulphur dioxide, ideal for portable and fixed gas detectors. |
Life expectancy
> 12 months
|
Measurement range
0-100 ppm
|
Target Gas
Sulphur dioxide
|
Response Time
< 30 seconds (T90)
|
Output
370 ± 70 nA/ppm
|