Electrochemical
Electrochemical
Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output |
---|---|---|---|---|---|---|
|
GS+4H2S DD Scientific - Electrochemical Cell for Hydrogen Sulphide |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
700 ± 250 nA/ppm
|
|
GS+4NH3-100 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 40 seconds (T90)
|
Output
100 ± 30 nA/ppm
|
|
GS+4NH3-1000 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-1000 ppm
|
Target Gas
Ammonia
|
Response Time
< 60 seconds (T90)
|
Output
8 ± 4 nA/ppm
|
|
GS+4NH3-300 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-300 ppm
|
Target Gas
Ammonia
|
Response Time
< 40 seconds (T90)
|
Output
40 ± 15 nA/ppm
|
|
GS+4NO2 Electrochemical cell for nitrogen dioxide, ideal for portable and fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0 – 30 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 30 seconds (T90)
|
Output
600 ± 150 nA/ppm
|
|
GS+4SO2 Electrochemical cell for sulphur dioxide, ideal for portable and fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Sulphur dioxide
|
Response Time
< 30 seconds (T90)
|
Output
500 ± 100 nA/ppm
|
|
GS+7CO Electrochemical cell for carbon monoxide, indicated for industrial application. |
Life expectancy
> 24 months
|
Measurement range
0-1000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|
GS+7ETO Electrochemical cell for ethylene oxide, ideal for many fixed instrument applications. |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Ethylene Oxide
|
Response Time
< 120 seconds (T90)
|
Output
2.5 ± 0.7 μA/ppm
|
|
GS+7H2S DD Scientific - Electrochemical Cell for Hydrogen Sulphide |
Life expectancy
> 24 months
|
Measurement range
0-200 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 40 seconds (T90)
|
Output
370 ± 100 nA/ppm
|
|
GS+7NH3-100 Electrochemical cell for ammonia. Ideally for industrial application, in particular for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 40 seconds (T90)
|
Output
115 ± 45 nA/ppm
|