Gas sensors
Gas sensors
Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Operating temperature | Output |
---|---|---|---|---|---|---|---|---|---|
|
D-300 NDIR module for the measure of CO2 |
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
|
D-300-3V NDIR module for the measure of CO2 |
Accuracy
± 300ppm ± 3% of reading
± 30ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Anidride Carbonica
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
|
EDI010106P The Gascheck board is a low cost infrared board for CO2 detection. |
Power Supply
15V DC
|
Measurement range
0-10%
|
Target Gas
Carbon dioxide
|
Output
0-1V, not linear
|
||||
|
EDI010107P The Gascheck board is a low cost infrared board for CO2 detection. |
Power Supply
15V DC
|
Measurement range
0-10%
|
Target Gas
Carbon dioxide
|
Output
4-20 mA, linear
|
||||
|
EDI030107NG The Gascard NG is a OEM board with infrared sensor for the measuring of CO2. |
Power Supply
24V DC (7-30V)
|
Measurement range
0-10%
|
Target Gas
Carbon dioxide
|
Output
0-20 mA
|
||||
|
EDI030207NG The Gascard NG is a OEM board with infrared sensor for the measuring of CH4. |
Power Supply
24V DC (7-30V)
|
Measurement range
0-10%
|
Target Gas
Methane
|
Output
0-20 mA
|
||||
|
EDI030307NG The Gascard NG is a OEM board with infrared sensor for the measuring of CO. |
Power Supply
24V DC (7-30V)
|
Measurement range
0-10%
|
Target Gas
Carbon Monoxide
|
Output
0-20 mA
4-20 mA
|
||||
|
EDI050103NG Chillcard NG is a board with infrared sensor for the detection of refrigerant gases. |
Power Supply
24V DC (7-30V)
|
Measurement range
0-10%
|
Target Gas
Carbon Monoxide
|
Output
0-20 mA
4-20 mA
|
||||
|
EDI080114NG Guardian NG is a stand-alone analyzer for CO2, with infrared sensor technology. |
Power Supply
from 90 to 260 VAC
|
Measurement range
0-10%
|
Target Gas
Carbon dioxide
|
Output
0-20 mA
4-20 mA
|
||||
|
EDI080203NG Guardian NG is a stand-alone analyzer for CH4, with infrared sensor technology. |
Power Supply
from 90 to 260 VAC
|
Measurement range
0-10%
|
Target Gas
Methane
|
Output
0-20 mA
4-20 mA
|