Gas sensors
Gas sensors
Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Operating temperature | Output |
---|---|---|---|---|---|---|---|---|---|
|
CD-100 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
24 VAC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
-40°C / 40°C
|
Output
RS485
0-20 mA
4-20 mA
0-10 Vdc
2-12 Vdc
|
|
CD-200 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
24 VAC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-2000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-99% RH
0-95% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
RS485
0-20 mA
2-10 Vdc
4-20 mA
0-10 Vdc
Relay
|
|
CD-300 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
|
CD-300-D3 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
4-20 mA
0-10 Vdc
2-10 Vdc
0-20 mA
|
|
CD-400 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Accuracy
± 50ppm ± 5% of reading
|
Power Supply
24 VAC
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
Relay
|
|
H-250-12V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
50 x 69 x 20 mm
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
PWM
I2C
UART
Analog (0.5V - 4.5V)
|
|
H-250-3V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
|
H-250-5V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
I2C
PWM
UART
Analog (0.5V - 4.5V)
|
|
S-110 NDIR module for the measure of CO2. With its compact size it is particularly suitable for several applications. |
Accuracy
± 30ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
Analog (0.5V - 4.5V)
I2C
UART
|
|
S-110H NDIR module for the measure of CO2. |
Accuracy
± 50ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
39 x 32 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Humidity range
0-99% RH
0-95% RH
|
Target Gas
Carbon dioxide
|
Operating temperature
-10°C / +60°C
|
Output
UART
I2C
PWM
Analog (0.5V - 4.5V)
|