Gas sensors
Gas sensors
Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Operating temperature | Output |
---|---|---|---|---|---|---|---|---|---|
|
C2H4-D3-3V NDIR module for the measure of Ethylene (C2H4) |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Ethylene
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
|
C2H4-LD-3V NDIR module for the measure of Ethylene |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-2000 ppm
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Ethylene
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
|
C2H4-LF-3V NDIR module for the measure of Ethylene. |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-2000 ppm
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Ethylene
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
|
C2H4-S3-3V NDIR module for the measure of Ethylene |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-100% LEL
0-27000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Ethylene
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
PWM
Analog (0.5V - 3.0V)
|
|
C3H8-D3-3V NDIR module for the measure of Propane (C3H8) |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-21000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Propane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
|
C3H8-LD-3V NDIR module for the measure of Propane |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-5000 ppm
0-21000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Propane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
|
C3H8-LF-3V NDIR module for the measure of Propane. |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-5000 ppm
0-21000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Propane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
|
C3H8-S3-3V NDIR module for the measure of Propane. |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-100% LEL
0-21000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Propane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
PWM
Analog (0.5V - 3.0V)
UART
|
|
C4H10-D3-3V NDIR module for the measure of Butane (C4H10) |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-18000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Butane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
PWM
Analog (0.5V - 3.0V)
|
|
C4H10-LD-3V NDIR module for the measure of Butane. |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-5000 ppm
0-18000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Butane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|