Gas sensors
Gas sensors
Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Working temperature | Output | Operating temperature |
---|---|---|---|---|---|---|---|---|---|---|
|
B-530 NDIR module for the measure of CO2. With its compact size and availability in Moisture proof version too, it is particularly suitable for agricultural field. |
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
65 x 50 x 20 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-5%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Working temperature
-20°C / +65°C
|
Output
UART
Analog (0.5V - 4.5V)
|
|
|
D-300 NDIR module for the measure of CO2 |
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Operating temperature
-20°C / +50°C
|
|
|
D-300-3V NDIR module for the measure of CO2 |
Accuracy
± 300ppm ± 3% of reading
± 30ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Anidride Carbonica
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Operating temperature
-20°C / +50°C
|
|
|
D-400 NDIR dual beam module for the measure of CO2. With its compact size it is particularly suitable for several applications. |
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
50 x 69 x 26 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Operating temperature
-20°C / +50°C
|
|
|
D-400-3V Modulo dual beam NDIR per la misura della CO2. Grazie al suo formato compatto risulta adatto per svariate applicazioni dall'HVAC alle serre. |
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
50 x 69 x 26 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Operating temperature
-20°C / +50°C
|
|
|
H-250-12V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
50 x 69 x 20 mm
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Output
PWM
I2C
UART
Analog (0.5V - 4.5V)
|
Operating temperature
-10°C / +60°C
|
|
|
H-250-3V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Operating temperature
-10°C / +60°C
|
|
|
H-250-5V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 4.5V)
|
Operating temperature
-10°C / +60°C
|
|
|
MT-200 Modulo USB NDIR per la misura di CO2 per Qualità dell'aria. |
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
USB
|
Dimension
55.6 x 19.4 x 10.3 mm
|
Measurement range
0-10000 ppm
0-5%
0-10%
|
Humidity range
0-95% RH
|
Target Gas
Carbon dioxide
|
Output
USB
|
Operating temperature
-20°C / +60°C
|
|
|
S-300 NDIR module for the measure of CO2. With its compact size it is particularly suitable for several applications. |
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Working temperature
-10°C / 60°C
|
Output
PWM
UART
I2C
Analog (0.5V - 4.5V)
|