Gas sensors
Gas sensors
Product | Description | Life expectancy | Output | Measurement range | Target Gas | Response Time |
---|---|---|---|---|---|---|
|
3HLM City Technology - cella elettrochimica per Acido Solfidrico |
Life expectancy
> 12 months
|
Output
370 ± 70 nA/ppm
|
Measurement range
0-200 ppm
|
Target Gas
Hydrogen Sulfide
|
Response Time
< 70 seconds (T90)
|
|
7HHLM City Technology - Electrochemical Cell for Hydrogen Sulfide |
Life expectancy
> 12 months
|
Output
1.7 ± 0.3 μA/ppm
|
Measurement range
0-50 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
|
C/Y City Technology - Electrochemical Cell for Oxygen for general purpose |
Life expectancy
> 12 months
|
Output
0.80 ± 0.12 mA in air
|
Measurement range
0-25% Oxygen
|
Target Gas
Oxygen
|
Response Time
<10 seconds (T95)
|
|
COCl2 3E 1 City Technology - Electrochemical Cell for Phosgene |
Life expectancy
> 12 months
|
Output
650 ± 150 nA/ppm
|
Measurement range
0-1 ppm
|
Target Gas
Phosgene
|
Response Time
< 120 seconds (T90)
|
|
GS+4NO Electrochemical cell for nitroc oxide, ideal for portable and fixed gas detectors. |
Life expectancy
> 12 months
|
Output
400 ± 100 nA/ppm
|
Measurement range
0 - 250 ppm
|
Target Gas
Nitrogen monoxide
|
Response Time
< 40 seconds (T90)
|
|
GS+7CL2 Electrochemical cell for chlorine, ideal for fixed gas detectors. |
Life expectancy
> 12 months
|
Output
1.0 ± 0.3 μA/ppm
|
Measurement range
0 - 20 ppm
|
Target Gas
Chlorine
|
Response Time
< 60 seconds (T90)
|
|
GS+7NO Electrochemical cell for nitric oxide, ideal for fixed gas detector. |
Life expectancy
> 12 months
|
Output
550 ± 150 nA/ppm
|
Measurement range
0-100 ppm
|
Target Gas
Nitrogen monoxide
|
Response Time
< 30 seconds (T90)
|
|
GS+7SO2 Electrochemical cell for sulphur dioxide, ideal for portable and fixed gas detectors. |
Life expectancy
> 12 months
|
Output
370 ± 70 nA/ppm
|
Measurement range
0-100 ppm
|
Target Gas
Sulphur dioxide
|
Response Time
< 30 seconds (T90)
|