Gas sensors
Gas sensors
Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Operating temperature | Output |
---|---|---|---|---|---|---|---|---|---|
|
CH4-CD300 Transmitter board with NDIR sensor for Methane (CH4) |
Accuracy
± 3% F.S.
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-100% LEL
0-50000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Methane
|
Operating temperature
-20°C / +50°C
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
|
CH4-D3 NDIR module for the measure of CH4 |
Accuracy
± 3% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-50000 ppm
|
Humidity range
0-99% RH
0-95% RH
|
Target Gas
Methane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
|
CH4-D3-3V NDIR module for the measure of Methane (CH4) |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-50000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Methane
|
Operating temperature
-20°C / +50°C
|
Output
PWM
I2C
UART
Analog (0.5V - 3.0V)
|
|
CH4-LD-3V NDIR module for the measure of CH4 |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-5000 ppm
0-50000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Methane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
Analog (0.5V - 3.0V)
UART
|
|
CH4-LF-3V NDIR module for the measure of CH4 |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
40 x 38 x 18.5 mm
|
Measurement range
0-5000 ppm
0-50000 ppm
|
Humidity range
0-99% RH
0-95% RH
|
Target Gas
Methane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
|
|
CH4-S3 NDIR module for the measure of CH4 |
Accuracy
± 3% F.S.
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-100% LEL
0-50000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Methane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
PWM
Analog (0.5V - 4.5V)
|
|
CH4-S3-3V NDIR module for the measure of CH4 |
Accuracy
± 3% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Measurement range
0-100% LEL
0-50000 ppm
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Methane
|
Operating temperature
-20°C / +50°C
|
Output
I2C
UART
PWM
Analog (0.5V - 3.0V)
|
|
M-530 Transmitter board based on CO2 NDIR sensor |
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
9~15 VDC
|
Dimension
123 x 70 x 43 mm
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-50000 ppm
|
Humidity range
0-95% RH
|
Operating temperature
0°C / +50°C
|
Output
UART
Analog (0.5V - 4.5V)
|