Gas sensors
Gas sensors
Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output |
---|---|---|---|---|---|---|
|
F2 3E 1 City Technology - Electrochemical cell for Fluorine |
Life expectancy
> 18 months
|
Measurement range
0-1 ppm
|
Target Gas
Fluorine
|
Response Time
< 80 seconds (T90)
|
Output
1 ± 0.3 μA/ppm
|
|
HCN 2E 30 F City Technology - Electrochemical Cell for Hydrogen cyanide HCN |
Life expectancy
> 18 months
|
Measurement range
0 – 30 ppm
|
Target Gas
Hydrogen cyanide
|
Response Time
< 30 seconds (T90)
|
Output
30 ± 15 nA/ppm
|
|
HF 3E 10 SE City Technology (Sensoric) - 3 Electrode sensor for Hydrofluoric Acid (HF) |
Life expectancy
> 18 months
|
Measurement range
0-10 ppm
|
Target Gas
Hydrofluoric acid
|
Response Time
< 90 seconds (T90)
|
Output
300 ± 100 nA/ppm
|
|
NH3 3E 100 City Technology - 3 Electrode Electrochemical Cell for Ammonia with organic electrolyte |
Life expectancy
> 18 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 120 seconds (T90)
|
Output
90 ± 40 nA/ppm
|
|
NH3 3E 1000 City Technology - 3 Electrode Electrochemical Cell with organic electrolyte for Ammonia |
Life expectancy
> 18 months
|
Measurement range
0-1000 ppm
|
Target Gas
Ammonia
|
Response Time
< 120 seconds (T90)
|
Output
6 ± 3 nA/ppm
|
|
O3 3E 1 F City Technology (Sensoric) - 3 Electrode sensor with organic electrolyte for Ozone (O3) |
Life expectancy
> 18 months
|
Measurement range
0-1 ppm
|
Target Gas
Ozone
|
Response Time
< 60 seconds (T90)
|
Output
450 ± 150 nA/ppm
|
Discontinued
|
H2S-2E-30 City Technology (Sensoric) - 2 Electrode sensor with organic electrolyte for Hydrogen sulfide (AsH3) |
Life expectancy
> 18 months
|
Measurement range
0 – 30 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
60 ± 30 nA/ppm
|