| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature | Output type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3M City Technology - 3 Electrode Electrochemical Cell for Carbon Monoxide (CO) |
Life expectancy
> 3 years
|
Measurement range
0-40.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
7 ± 2 nA/ppm
|
||||||
|
3MF City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-40.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
7 ± 2 nA/ppm
|
||||||
|
5MF City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-40.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 40 seconds (T90)
|
Output
10 ± 4 nA/ppm
|
||||||
|
H-250-12V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
PWM
I2C
UART
Analog (0.5V - 4.5V)
|
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
50 x 69 x 20 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
|||
|
H-250-3V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
|||
|
H-250-5V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 4.5V)
|
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
|||
|
H2 3E 4 % City Technology - Electrochemical Cell for Hydrogen |
Life expectancy
> 24 months
|
Measurement range
0-40.000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 60 seconds (T90)
|
Output
1.0 ± 0.5 nA/ppm
|
||||||
|
Discontinued
|
LGD COMPACT-A CH4 LGD Compact A is a module with laser technology (TDLS) idea for very low gas concentration |
Measurement range
0-100 ppm
0-40.000 ppm
|
Target Gas
Methane
|
Power Supply
10-30 Vdc
|
Output type
RS232
4-20 mA
0-5 V
|