Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Energetic consumption | Temperature range | Output formats | Temp. drift |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
3NFF City Technology - Electrochemical Cell for Nitrogen Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-1000 ppm
|
Target Gas
Nitrogen monoxide
|
Response Time
< 25 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|||||
|
4NT City Technology - Electrochemical Cell for Nitrogen Monoxide |
Life expectancy
> 24 months
|
Measurement range
0 - 250 ppm
|
Target Gas
Nitrogen monoxide
|
Response Time
< 40 seconds (T90)
|
Output
400 ± 80 nA/ppm
|
|||||
|
GS+4NO Electrochemical cell for nitroc oxide, ideal for portable and fixed gas detectors. |
Life expectancy
> 12 months
|
Measurement range
0 - 250 ppm
|
Target Gas
Nitrogen monoxide
|
Response Time
< 40 seconds (T90)
|
Output
400 ± 100 nA/ppm
|
|||||
|
GS+7NO Electrochemical cell for nitric oxide, ideal for fixed gas detector. |
Life expectancy
> 12 months
|
Measurement range
0-100 ppm
|
Target Gas
Nitrogen monoxide
|
Response Time
< 30 seconds (T90)
|
Output
550 ± 150 nA/ppm
|
|||||
|
INFRA.sens® AK2 SF6 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
<1 Vol.%
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analogic
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
|||
|
INFRA.sens® AK20 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
<1 Vol.%
|
Target Gas
Multigas
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Output formats
RS232, Can, Analogica
|
Temp. drift
3 secondi (T90)
|
|||
|
INFRA.sens® AK250TBH The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
<100 Vol.%
|
Target Gas
Multigas
|
Response Time
3 secondi (T90)
|
Output
RS232, Can, Analogica
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
|||
|
Infra.Sens AK100 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
< 1 Vol.%
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
|||
|
Infra.Sens AK250 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
< 2000ppm
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
|||
|
Infra.Sens AK5 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
< 100 Vol.%
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|