Gas sensors
Gas sensors
| Product | Description | Power Supply | Measurement range | Target Gas | Output | Accuracy | Energetic consumption | Temperature range | Response Time | Output formats | Temp. drift | Compatible sensors |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CDM7162-C00 Pre-calibrated CO2 module uses a compact NDIR CO2 sensor. |
Power Supply
4.5-5.25 VDC
|
Measurement range
360-5000 ppm CO2
|
Target Gas
Carbon dioxide
|
Output
UART
PWM
I2C
|
|||||||
|
HUMI.sens Humidity sensor Humidity sensor | |||||||||||
|
INFRA.sens® AK2 SF6 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
<1 Vol.%
|
Target Gas
Multigas
|
Output
RS232, Can, Analogic
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 seconds (T90)
|
||||
|
INFRA.sens® AK20 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
<1 Vol.%
|
Target Gas
Multigas
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Output formats
RS232, Can, Analogica
|
Temp. drift
3 secondi (T90)
|
||||
|
INFRA.sens® AK250TBH The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
<100 Vol.%
|
Target Gas
Multigas
|
Output
RS232, Can, Analogica
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 secondi (T90)
|
||||
|
INLINE Safety Filter Safety filter |
Compatible sensors
Gas Analyzer Equipment
|
||||||||||
|
Infra.Sens AK100 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
< 1 Vol.%
|
Target Gas
Multigas
|
Output
RS232, Can, Analog
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 seconds (T90)
|
||||
|
Infra.Sens AK250 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
< 2000ppm
|
Target Gas
Multigas
|
Output
RS232, Can, Analog
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 seconds (T90)
|
||||
|
Infra.Sens AK5 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
< 100 Vol.%
|
Target Gas
Multigas
|
Output
RS232, Can, Analog
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 seconds (T90)
|
||||
|
Infra.Sens AK50 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
< 20 Vol.%
|
Target Gas
Multigas
|
Output
RS232, Can, Analog
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
Response Time
3 seconds (T90)
|