Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Sensors | Power Supply | Dimension | Housing | Weight (grams) | Resolution | Working temperature | Sensor type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3HH City Technology - Electrochemical Cell for Hydrogen Sulfide |
Life expectancy
> 24 months
|
Measurement range
0-50 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
1.70 ± 0.30 μA/ppm
|
||||||||
|
3HHLM City Technology - electrochemical cell for Hydrogen Sulfide |
Life expectancy
24 months
|
Measurement range
0-50 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
1.7 ± 0.3 μA/ppm
|
||||||||
|
7HH City Technology - Electrochemical Cell for Hydrogen Sulfide |
Life expectancy
> 24 months
|
Measurement range
0-50 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
1.7 ± 0.3 μA/ppm
|
||||||||
|
7HHLM City Technology - Electrochemical Cell for Hydrogen Sulfide |
Life expectancy
> 12 months
|
Measurement range
0-50 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
1.7 ± 0.3 μA/ppm
|
||||||||
|
7HL City Technology - Electrochemical Cell for Hydrogen Chloride |
Life expectancy
> 24 months
|
Measurement range
0-50 ppm
|
Target Gas
Hydrogen Chloride
|
Response Time
< 120 seconds (T90)
|
Output
750 ± 250 nA/ppm
|
||||||||
|
Cl2 3E 50 City Technology - Electrochemical Cell for Chlorine |
Life expectancy
> 24 months
|
Measurement range
0-50 ppm
|
Target Gas
Chlorine
|
Response Time
< 60 seconds (T90)
|
Output
450 ± 200 nA/ppm
|
||||||||
|
NO2 3E 50 City Technology - Electrochemical Cell for Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-50 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 30 seconds (T90)
|
Output
200 ± 40 nA/ppm
|
||||||||
|
SiH4 3E 50 LT City Technology - Electrochemical cell for Silane |
Life expectancy
> 24 months
|
Measurement range
0-50 ppm
|
Target Gas
Silane
|
Response Time
< 60 seconds (T90)
|
Output
130 ± 70 nA/ppm
|
||||||||
|
Discontinued
|
SE100GF-T Digital handheld gas leakage detector, for hydrocarbons. |
Measurement range
0 - 10.000 ppm CH4
0 - 1% VOL CH4
0 - 20% LEL CH4
0 - 1.800 ppm LPG
|
Sensors
Semiconductor
|
Power Supply
Batteries
|
Dimension
72 x 151 x 37 mm
|
Housing
ABS HG
|
Weight (grams)
312 g
|
Resolution
1 ppm
|
Working temperature
0°C / 45°C
|
|||||
|
Discontinued
|
SE200GF-T Digital handheld gas leakage detector, for hydrocarbons with rechargable Li-Po Battery Pack |
Measurement range
0 - 10.000 ppm CH4
0 - 1% VOL CH4
0 - 20% LEL CH4
0 - 1.800 ppm LPG
|
Power Supply
Batteries
|
Dimension
72 x 151 x 37 mm
|
Housing
ABS HB
|
Weight (grams)
312 g
|
Resolution
1 ppm
|
Working temperature
0°C / 45°C
|
Sensor type
Semiconductor
|