Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
AQ3ND City Technology - Electrochemical cell for Nitrogen Dioxide Air Quality cell |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 120 seconds (T90)
|
Output
1.029 ± 0.294 mV/ppb
|
|||||
|
AQ3OZ City Technology - Electrochemical cell for Ozone |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Ozone
|
Response Time
< 120 seconds (T90)
|
Output
1.20 ± 0.50 mV/ppb
|
|||||
|
AQ3STF City Technology - Electrochemical cell for Sulfur Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Sulfur Dioxide
|
Response Time
< 40 seconds (T90)
|
Output
0.218 ± 0.044mV/ppb
|
|||||
|
ASH3-3E-1 City Technology (Sensoric) - 3 Electrode sensor with ionic liquid electrolyte for Arsine (AsH3) |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Arsine
|
Response Time
< 30 seconds (T90)
|
Output
1.4 ± 0.45 μA/ppm
|
|||||
|
B2H6 3E 1 LT City Technology - Electrochemical cell for Diborane |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Diborane
|
Response Time
< 30 seconds (T90)
|
Output
2.2 ± 0.5 μA/ppm
|
|||||
|
COCl2 3E 1 City Technology - Electrochemical Cell for Phosgene |
Life expectancy
> 12 months
|
Measurement range
0-1 ppm
|
Target Gas
Phosgene
|
Response Time
< 120 seconds (T90)
|
Output
650 ± 150 nA/ppm
|
|||||
|
F2 3E 1 City Technology - Electrochemical cell for Fluorine |
Life expectancy
> 18 months
|
Measurement range
0-1 ppm
|
Target Gas
Fluorine
|
Response Time
< 80 seconds (T90)
|
Output
1 ± 0.3 μA/ppm
|
|||||
|
H-250-12V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
PWM
I2C
UART
Analog (0.5V - 4.5V)
|
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
50 x 69 x 20 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
||
|
H-250-3V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
||
|
H-250-5V NDIR module for the measure of high concentration of Carbon Dioxide (CO2) |
Measurement range
0-5%
0-10%
0-15%
0-20%
0-25%
|
Target Gas
Carbon dioxide
|
Output
I2C
PWM
UART
Analog (0.5V - 4.5V)
|
Accuracy
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
32.5 x 38 x 19.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|