| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Working temperature | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AQ3ND City Technology - Electrochemical cell for Nitrogen Dioxide Air Quality cell |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 120 seconds (T90)
|
Output
1.029 ± 0.294 mV/ppb
|
||||||
|
AQ3OZ City Technology - Electrochemical cell for Ozone |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Ozone
|
Response Time
< 120 seconds (T90)
|
Output
1.20 ± 0.50 mV/ppb
|
||||||
|
AQ3STF City Technology - Electrochemical cell for Sulfur Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Sulfur Dioxide
|
Response Time
< 40 seconds (T90)
|
Output
0.218 ± 0.044mV/ppb
|
||||||
|
ASH3-3E-1 City Technology (Sensoric) - 3 Electrode sensor with ionic liquid electrolyte for Arsine (AsH3) |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Arsine
|
Response Time
< 30 seconds (T90)
|
Output
1.4 ± 0.45 μA/ppm
|
||||||
|
B2H6 3E 1 LT City Technology - Electrochemical cell for Diborane |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Diborane
|
Response Time
< 30 seconds (T90)
|
Output
2.2 ± 0.5 μA/ppm
|
||||||
|
COCl2 3E 1 City Technology - Electrochemical Cell for Phosgene |
Life expectancy
> 12 months
|
Measurement range
0-1 ppm
|
Target Gas
Phosgene
|
Response Time
< 120 seconds (T90)
|
Output
650 ± 150 nA/ppm
|
||||||
|
F2 3E 1 City Technology - Electrochemical cell for Fluorine |
Life expectancy
> 18 months
|
Measurement range
0-1 ppm
|
Target Gas
Fluorine
|
Response Time
< 80 seconds (T90)
|
Output
1 ± 0.3 μA/ppm
|
||||||
|
O3 3E 1 F City Technology (Sensoric) - 3 Electrode sensor with organic electrolyte for Ozone (O3) |
Life expectancy
> 18 months
|
Measurement range
0-1 ppm
|
Target Gas
Ozone
|
Response Time
< 60 seconds (T90)
|
Output
450 ± 150 nA/ppm
|
||||||
|
T-110 As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-10%
0.04-5%
0.04-3%
0.04-2%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19 x 29.3 x 8.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Working temperature
0°C / 50°C
|
|||
|
T-110-3V As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application. |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0-2%
0-3%
0-5%
0-10%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
19 x 29.3 x 8.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
0°C / +50°C
|