Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Power Supply |
|---|---|---|---|---|---|---|---|
|
A3OZ City Technology 4 Electrode environmental monitoring sensor for Ozone and Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-10 ppm
|
Target Gas
Ozone
Nitrogen dioxide
|
Response Time
< 40 seconds (T90)
|
Output
2.2 ± 0.5 μA/ppm
|
|
|
A3STF City Technology - Electrochemical Cell for Sulfur Dioxide |
Life expectancy
> 3 years
|
Measurement range
0-10 ppm
|
Target Gas
Sulfur Dioxide
|
Response Time
< 40 seconds (T90)
|
Output
600 ± 120 nA/ppm
|
|
|
AQ3CO City Technology - Electrochemical cell for Carbon Monoxide Air Quality cell |
Life expectancy
> 24 months
|
Measurement range
0-10 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 60 seconds (T90)
|
Output
0.0726 ± 0.0145mV/ppb
|
|
|
Cl2 3E 10 City Technology - Electrochemical Cell for Chlorine |
Life expectancy
> 4 years
|
Measurement range
0-10 ppm
|
Target Gas
Chlorine
|
Response Time
< 60 seconds (T90)
|
Output
450 ± 200 nA/ppm
|
|
|
GS+4CL2 Electrochemical cell for chlorine, ideal for portable and fixed gas detectors. |
Life expectancy
> 1 year in air
|
Measurement range
0-10 ppm
|
Target Gas
Chlorine
|
Response Time
< 60 seconds (T90)
|
Output
600 ± 200 nA/ppm
|
|
|
HF 3E 10 SE City Technology (Sensoric) - 3 Electrode sensor for Hydrofluoric Acid (HF) |
Life expectancy
> 18 months
|
Measurement range
0-10 ppm
|
Target Gas
Hydrofluoric acid
|
Response Time
< 90 seconds (T90)
|
Output
300 ± 100 nA/ppm
|
|
|
TEC-OXY-D0-ZZ Oxygen measurement module in various ranges between 10ppm and 96% based on zirconium oxide sensor. |
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
0-10V, linear
4-20 mA, linear
|
Power Supply
12 - 24 Vdc
|
||
|
TEC-OXY-D1-ZZ Oxygen measurement module in various ranges between 10ppm and 96% based on zirconium oxide sensor |
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
4-20 mA, linear
0-10V, linear
RS485
Relay
|
Power Supply
12 - 24 Vdc
|
||
|
TEC-OXY-D2-ZZ Oxygen measurement module in various ranges between 10ppm and 96% based on zirconium oxide sensor. |
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
4-20 mA, linear
0-10V, linear
RS485
USB
RS232
Relay
|
Power Supply
12 - 24 Vdc
|
||
|
TEC-OXY-D3-ZZ Oxygen measurement module with display in various ranges between 10ppm and 96% based on zirconium oxide sensor. |
Measurement range
10-1.000 ppm
0.05-1 %
0.05-2 %
0.05-3 %
0.1-25 %
0.1-95 %
0.1-96 %
|
Target Gas
Oxygen
|
Output
4-20 mA, linear
0-10V, linear
RS485
USB
RS232
Relay
|
Power Supply
12 - 24 Vdc
|