Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Compatible sensors | Accuracy | Energetic consumption | Temperature range |
|---|---|---|---|---|---|---|---|---|---|---|
|
3HYE City Technology - 3 Electrode Electrochemical Cell for Hydrogen |
Life expectancy
> 24 months
|
Measurement range
0-10.000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 70 seconds (T90)
|
Output
3 ± 1 nA/ppm
|
||||
|
7HYE City Technology - Electrochemical Cell for Hydrogen |
Life expectancy
> 24 months
|
Measurement range
0-10.000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 110 seconds (T90)
|
Output
3 ± 1 nA/ppm
|
||||
|
A5F+ City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
60 ± 20 nA/ppm
|
||||
|
A5F+ City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
60 ± 20 nA/ppm
|
||||
|
EM5042A Evaluation module for the CO sensor TGS5042 |
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|
Compatible sensors
TGS5042
|
||||||
|
GS+4COHC Electrochemical cell for carbon monoxide, indicated for high concentration applications. |
Life expectancy
> 2 years in air
|
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 40 seconds (T90)
|
Output
20 ± 10 nA/ppm
|
||||
|
H2 3E 1% City Technology - Electrochemical Cell for Hydrogen |
Life expectancy
> 24 months
|
Measurement range
0-10.000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 70 seconds (T90)
|
Output
10 ± 5 nA/ppm
|
||||
|
Infra.Sens AK50 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
< 20 Vol.%
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
||
|
Discontinued
|
EM5342 Evaluation module EM5342 for the gas sensor TGS5342. |
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|
Compatible sensors
TGS5342
|
||||||
|
Discontinued
|
TGS5042-B00 Figaro’s TGS5042 is a battery operable electrochemical sensor which offers several advantages over traditional electrochemical sensors. |
Measurement range
0-10.000 ppm
|
Target Gas
Carbon Monoxide
|