Gas sensors
Gas sensors
| Product | Description | Application field | Heater consumption | Measurement range | Target Gas | Response Time | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature | Output | Working temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CGM6812-B00 The CGM6812-B00 is a pre-calibrated module for combustible gases. |
Application field
Industrial
|
Heater consumption
≤1.5W
|
Measurement range
0-14.000 ppm
|
Target Gas
Hydrogen
Propane
Methane
Isobutane
|
Response Time
< 30 seconds (T90)
|
|||||||
|
IoT-S300E NDIR module for CO2 measurement |
Measurement range
400-5000 ppm
|
Target Gas
Carbon dioxide
|
Accuracy
± 50ppm ± 5% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
|
Operating temperature
-10°C / +50°C
|
Output
I2C
UART
|
||||
|
IoT-S300E-3V NDIR module for CO2 measurement |
Measurement range
400-5000 ppm
|
Target Gas
Carbon dioxide
|
Accuracy
± 50ppm ± 5% of reading
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
|
Operating temperature
-10°C / +50°C
|
Output
I2C
UART
|
||||
|
T-110 As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-10%
0.04-5%
0.04-3%
0.04-2%
|
Target Gas
Carbon dioxide
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19 x 29.3 x 8.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Working temperature
0°C / 50°C
|
||||
|
T-110-3V As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application. |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0-2%
0-3%
0-5%
0-10%
|
Target Gas
Carbon dioxide
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
19 x 29.3 x 8.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
0°C / +50°C
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
||||
|
T-200 NDIR module for CO2 measurement |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Target Gas
Anidride Carbonica
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19.4 x 30 x10.3 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +60°C
|
Output
I2C
UART
Analogica (0.5V - 4.5V)
PWM
|
||||
|
T-200-3V NDIR module for CO2 measurement. |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Target Gas
Anidride Carbonica
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
19.4 x 30 x10.3 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +60°C
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
||||
|
T-300A Miniature NDIR module for the measure of CO2. Designed for customers in residential buildings, offices, or cabin of vehicles, or so. |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
|
Target Gas
Carbon dioxide
|
Accuracy
± 25ppm ± 5% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19 x 31 x 7.9 mm
|
Humidity range
0-95% RH
|
Operating temperature
-10°C / +60°C
|
Output
I2C
UART
PWM
|
||||
|
T-300A-3V Miniature NDIR module for the measure of CO2. Designed for customers in residential buildings, offices, or cabin of vehicles, or so. |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
|
Target Gas
Carbon dioxide
|
Accuracy
± 25ppm ± 5% of reading
|
Power Supply
3.3 Vdc
|
Dimension
19 x 31 x 7.9 mm
|
Humidity range
0-95% RH
|
Operating temperature
-10°C / +60°C
|
Output
I2C
UART
PWM
|
||||
|
Discontinued
|
FCM6812 Combustible gas sensor module |
Application field
Industrial
|
Measurement range
0-14.000 ppm
|
Target Gas
Isobutane
|