Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Working temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
2EF City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 24 months
|
Measurement range
0-200 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 40 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|||||
|
3H City Technology - Electrochemical Cell for Hydrogen Sulfide |
Life expectancy
> 24 months
|
Measurement range
0-200 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 35 seconds (T90)
|
Output
370 ± 70 nA/ppm
|
|||||
|
3HLM City Technology - cella elettrochimica per Acido Solfidrico |
Life expectancy
> 12 months
|
Measurement range
0-200 ppm
|
Target Gas
Hydrogen Sulfide
|
Response Time
< 70 seconds (T90)
|
Output
370 ± 70 nA/ppm
|
|||||
|
5ND City Technology - Electrochemical Cell for Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-200 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 60 seconds (T90)
|
Output
370 ± 70 nA/ppm
|
|||||
|
7H City Technology - Electrochemical cell for Hydrogen Sulfide |
Life expectancy
> 24 months
|
Measurement range
0-200 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 35 seconds (T90)
|
Output
370 ± 70 nA/ppm
|
|||||
|
7HLM City Technology - Electrochemical Cell for Hydrogen Sulfide |
Life expectancy
> 24 months
|
Measurement range
0-200 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 35 seconds (T90)
|
Output
370 ± 70 nA/ppm
|
|||||
|
GS+4DT Electrochemical cell for carbon monoxide and hydrogen sulfide, indicated for industrial application. |
Life expectancy
> 2 years in air
|
Measurement range
0-200 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
775 ± 275 nA/ppm
|
|||||
|
GS+7H2S DD Scientific - Electrochemical Cell for Hydrogen Sulphide |
Life expectancy
> 24 months
|
Measurement range
0-200 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 40 seconds (T90)
|
Output
370 ± 100 nA/ppm
|
|||||
|
S+4 2ECOH Electrochemical cell for carbon monoxide. |
Life expectancy
> 2 years
|
Measurement range
0-200 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
175 ± 50 nA/ppm
|
|||||
|
T-110 As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-10%
0.04-5%
0.04-3%
0.04-2%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19 x 29.3 x 8.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Working temperature
0°C / 50°C
|