Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
3E City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-1000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 25 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|||||
|
3EF City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-1000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|||||
|
3HYT City Technology - electrochemical cell for Hydrogen |
Life expectancy
> 24 months
|
Measurement range
0-1000 ppm
|
Target Gas
Hydrogen
|
Response Time
< 50 seconds (T90)
|
Output
30 ± 10 nA/ppm
|
|||||
|
3NFF City Technology - Electrochemical Cell for Nitrogen Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-1000 ppm
|
Target Gas
Nitrogen monoxide
|
Response Time
< 25 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|||||
|
5NF City Technology - Electrochemical Cell for Nitric Oxide |
Life expectancy
> 3 years
|
Measurement range
0-1000 ppm
|
Target Gas
Nitric Oxide
|
Response Time
< 30 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|||||
|
7E City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-1000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 25 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|||||
|
7EF City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-1000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|||||
|
A7EF City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-1000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 35 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|||||
|
CD-300 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
|
Target Gas
Carbon dioxide
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
||
|
D-300 NDIR module for the measure of CO2 |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|