Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Power Supply | Accuracy | Dimension | Humidity range | Working temperature | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A3CO City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 24 months
|
Measurement range
0-500 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 40 seconds (T90)
|
Output
200 ± 40 nA/ppm
|
||||||
|
CO 3E 300 City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 4 years
|
Measurement range
0-500 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 40 seconds (T90)
|
Output
70 ± 20 nA/ppm
|
||||||
|
EDI030100NG The Gascard NG is a OEM board with infrared sensor for the measuring of CO2. |
Measurement range
0-500 ppm
|
Target Gas
Carbon dioxide
|
Output
0-20 mA
|
Power Supply
24V DC (7-30V)
|
|||||||
|
GS+4CO2H Electrochemical cell for carbon monoxide, ideal for use in portable where H2 is an issue. |
Life expectancy
> 2 years in air
|
Measurement range
0-500 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
50 ± 20 nA/ppm
|
||||||
|
NH3 3E 500 SE City Technology - 3 Electrode Electrochemical Cell for Ammonia |
Life expectancy
> 24 months
|
Measurement range
0-500 ppm
|
Target Gas
Ammonia
|
Response Time
< 90 seconds (T90)
|
Output
35 ± 15 nA/ppm
|
||||||
|
T-110 As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-10%
0.04-5%
0.04-3%
0.04-2%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Power Supply
5.0 Vdc
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
19 x 29.3 x 8.5 mm
|
Humidity range
0-95% RH
0-99% RH
|
Working temperature
0°C / 50°C
|
|||
|
T-200 NDIR module for CO2 measurement |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
UART
Analogica (0.5V - 4.5V)
PWM
|
Power Supply
5.0 Vdc
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
19.4 x 30 x10.3 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +60°C
|
|||
|
T-200-3V NDIR module for CO2 measurement. |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Power Supply
3.3 Vdc
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Dimension
19.4 x 30 x10.3 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +60°C
|