Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
A3OZ City Technology 4 Electrode environmental monitoring sensor for Ozone and Nitrogen Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-10 ppm
|
Target Gas
Ozone
Nitrogen dioxide
|
Response Time
< 40 seconds (T90)
|
Output
2.2 ± 0.5 μA/ppm
|
|||||
|
A3STF City Technology - Electrochemical Cell for Sulfur Dioxide |
Life expectancy
> 3 years
|
Measurement range
0-10 ppm
|
Target Gas
Sulfur Dioxide
|
Response Time
< 40 seconds (T90)
|
Output
600 ± 120 nA/ppm
|
|||||
|
AQ3CO City Technology - Electrochemical cell for Carbon Monoxide Air Quality cell |
Life expectancy
> 24 months
|
Measurement range
0-10 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 60 seconds (T90)
|
Output
0.0726 ± 0.0145mV/ppb
|
|||||
|
CD-300 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
|
Target Gas
Carbon dioxide
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
||
|
Cl2 3E 10 City Technology - Electrochemical Cell for Chlorine |
Life expectancy
> 4 years
|
Measurement range
0-10 ppm
|
Target Gas
Chlorine
|
Response Time
< 60 seconds (T90)
|
Output
450 ± 200 nA/ppm
|
|||||
|
D-300 NDIR module for the measure of CO2 |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
D-300-3V NDIR module for the measure of CO2 |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Accuracy
± 300ppm ± 3% of reading
± 30ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
GS+4CL2 Electrochemical cell for chlorine, ideal for portable and fixed gas detectors. |
Life expectancy
> 1 year in air
|
Measurement range
0-10 ppm
|
Target Gas
Chlorine
|
Response Time
< 60 seconds (T90)
|
Output
600 ± 200 nA/ppm
|
|||||
|
HF 3E 10 SE City Technology (Sensoric) - 3 Electrode sensor for Hydrofluoric Acid (HF) |
Life expectancy
> 18 months
|
Measurement range
0-10 ppm
|
Target Gas
Hydrofluoric acid
|
Response Time
< 90 seconds (T90)
|
Output
300 ± 100 nA/ppm
|