Gas sensors
Gas sensors
| Product | Description | Accuracy | Power Supply | Dimension | Measurement range | Humidity range | Target Gas | Working temperature | Output | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|
|
T-110 As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application |
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19 x 29.3 x 8.5 mm
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-10%
0.04-5%
0.04-3%
0.04-2%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Working temperature
0°C / 50°C
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
|
|
T-110-3V As world’s smallest CO2 sensor module, T-110 Series are developed as residential indoor air-quality monitoring application. |
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
19 x 29.3 x 8.5 mm
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0-2%
0-3%
0-5%
0-10%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Operating temperature
0°C / +50°C
|
|
|
T-200 NDIR module for CO2 measurement |
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19.4 x 30 x10.3 mm
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Anidride Carbonica
|
Output
I2C
UART
Analogica (0.5V - 4.5V)
PWM
|
Operating temperature
-20°C / +60°C
|
|
|
T-200-3V NDIR module for CO2 measurement. |
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
19.4 x 30 x10.3 mm
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Humidity range
0-95% RH
0-99% RH
|
Target Gas
Anidride Carbonica
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Operating temperature
-20°C / +60°C
|
|
|
T-300A Miniature NDIR module for the measure of CO2. Designed for customers in residential buildings, offices, or cabin of vehicles, or so. |
Accuracy
± 25ppm ± 5% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19 x 31 x 7.9 mm
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
|
Humidity range
0-95% RH
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
PWM
|
Operating temperature
-10°C / +60°C
|
|
|
T-300A-3V Miniature NDIR module for the measure of CO2. Designed for customers in residential buildings, offices, or cabin of vehicles, or so. |
Accuracy
± 25ppm ± 5% of reading
|
Power Supply
3.3 Vdc
|
Dimension
19 x 31 x 7.9 mm
|
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
|
Humidity range
0-95% RH
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
PWM
|
Operating temperature
-10°C / +60°C
|
|
|
TGS2600 The TGS 2600 has high sensitivity to low concentrations of gaseous air contaminants such as hydrogen and carbon monoxide which exist in cigarette smoke. The sensor can detect hydrogen at a level of several ppm. |
Measurement range
1-30 ppm H2
|
Target Gas
Air pollutants
|