Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Power Supply | Supply voltage | Application field | Heater consumption |
|---|---|---|---|---|---|---|---|---|---|---|
|
3ETO City Technology - Electrochemical Cell for Ethylene Oxide |
Life expectancy
> 24 months
|
Measurement range
0-20 ppm
|
Target Gas
Ethylene Oxide
|
Response Time
< 140 seconds (T90)
|
Output
2.75 ± 0.5 μA/ppm
|
||||
|
4ETO City Technology - Electrochemical Cell for Ethylene Oxide |
Life expectancy
> 24 months
|
Measurement range
0-20 ppm
|
Target Gas
Ethylene Oxide
|
Response Time
< 120 seconds (T90)
|
Output
1.9 ± 0.5 μA/ppm
|
||||
|
7ETO City Technology - Electrochemical Cell for Ethylene Oxide |
Life expectancy
> 24 months
|
Measurement range
0-20 ppm
|
Target Gas
Ethylene Oxide
|
Response Time
< 140 seconds (T90)
|
Output
2.25 ± 0.65 μA/ppm
|
||||
|
EDI050102NG Chillcard NG is a board with infrared sensor for the detection of refrigerant gases. |
Measurement range
0-3%
|
Target Gas
Refrigerant gases
|
Output
0-20 mA
4-20 mA
|
Power Supply
24V DC (7-30V)
|
|||||
|
FCM2630-C01 Precalibrated module for the detection of low-flammable refrigerant gases such as R-32 |
Target Gas
Refrigerant gases
|
Supply voltage
5.0 Vdc
|
|||||||
|
GS+4ETO Electrochemical cell for ethylene oxide, ideal for many applications like fruit ripening. |
Life expectancy
> 2 years in air
|
Measurement range
0 - 20 ppm
|
Target Gas
Ethylene Oxide
|
Response Time
< 120 seconds (T90)
|
Output
1.9 ± 0.6 μA/ppm
|
||||
|
GS+7ETO Electrochemical cell for ethylene oxide, ideal for many fixed instrument applications. |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Ethylene Oxide
|
Response Time
< 120 seconds (T90)
|
Output
2.5 ± 0.7 μA/ppm
|
||||
|
TGS2630 Semiconductor gas sensor for refrigerant gas |
Measurement range
1,000-10,000ppm
|
Target Gas
Refrigerant gases
|
Application field
Industrial
|
||||||
|
TGS3830 The TGS3830 is a semiconductor sensor with a high sensitivity to R-134a, the most promising alternative to R-12, commonly used in air conditioning systems and refrigerators. |
Measurement range
5-100 ppm
|
Target Gas
Refrigerant gases
|
Application field
Industrial
|
Heater consumption
100 mW
|
|||||
|
Discontinued
|
EDI050101NG Chillcard NG is a board with infrared sensor for the detection of refrigerant gases. |
Measurement range
0-3000 ppm
|
Target Gas
Refrigerant gases
|
Output
0-20 mA
4-20 mA
|
Power Supply
24V DC (7-30V)
|