Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Working temperature | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AQ3ND City Technology - Electrochemical cell for Nitrogen Dioxide Air Quality cell |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Nitrogen dioxide
|
Response Time
< 120 seconds (T90)
|
Output
1.029 ± 0.294 mV/ppb
|
||||||
|
AQ3OZ City Technology - Electrochemical cell for Ozone |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Ozone
|
Response Time
< 120 seconds (T90)
|
Output
1.20 ± 0.50 mV/ppb
|
||||||
|
AQ3STF City Technology - Electrochemical cell for Sulfur Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Sulfur Dioxide
|
Response Time
< 40 seconds (T90)
|
Output
0.218 ± 0.044mV/ppb
|
||||||
|
ASH3-3E-1 City Technology (Sensoric) - 3 Electrode sensor with ionic liquid electrolyte for Arsine (AsH3) |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Arsine
|
Response Time
< 30 seconds (T90)
|
Output
1.4 ± 0.45 μA/ppm
|
||||||
|
B-530 NDIR module for the measure of CO2. With its compact size and availability in Moisture proof version too, it is particularly suitable for agricultural field. |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-5%
|
Target Gas
Carbon dioxide
|
Output
UART
Analog (0.5V - 4.5V)
|
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
65 x 50 x 20 mm
|
Humidity range
0-95% RH
0-99% RH
|
Working temperature
-20°C / +65°C
|
|||
|
B2H6 3E 1 LT City Technology - Electrochemical cell for Diborane |
Life expectancy
> 24 months
|
Measurement range
0-1 ppm
|
Target Gas
Diborane
|
Response Time
< 30 seconds (T90)
|
Output
2.2 ± 0.5 μA/ppm
|
||||||
|
CD-300 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
|
Target Gas
Carbon dioxide
|
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
|||
|
COCl2 3E 1 City Technology - Electrochemical Cell for Phosgene |
Life expectancy
> 12 months
|
Measurement range
0-1 ppm
|
Target Gas
Phosgene
|
Response Time
< 120 seconds (T90)
|
Output
650 ± 150 nA/ppm
|
||||||
|
D-300 NDIR module for the measure of CO2 |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Target Gas
Carbon dioxide
|
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
|||
|
D-300-3V NDIR module for the measure of CO2 |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Accuracy
± 300ppm ± 3% of reading
± 30ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|