Gas sensors
Gas sensors
| Product | Description | Life expectancy | Output | Measurement range | Target Gas | Response Time | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature | Working temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A02 Electrochemical cell for oxygen, range 0-100%, indicated for gas analyzer for automotive and for food storage applications. |
Life expectancy
> 24 months
|
Output
9 - 13 mV in air
|
Measurement range
0-100%
|
Target Gas
Oxygen
|
Response Time
< 5 seconds (T90)
|
||||||
|
A03 Electrochemical cell for oxygen, range 0-100%, indicated for gas analyzer for automotive and food storage applications. |
Life expectancy
> 24 months
|
Output
9 - 13 mV in air
|
Measurement range
0-100%
|
Target Gas
Oxygen
|
Response Time
< 5 seconds (T90)
|
||||||
|
AQM-100 AQM-100 series transmitters which can measure gases such as CO2, VOCs, Temperature, Humidity. |
Output
RS232
RS485
|
Measurement range
0-10000 ppm
|
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
12 Vdc
|
Dimension
118 x 74 x 22 mm
|
Humidity range
0-95% RH
|
Operating temperature
0°C / +50°C
|
||||
|
B-530 NDIR module for the measure of CO2. With its compact size and availability in Moisture proof version too, it is particularly suitable for agricultural field. |
Output
UART
Analog (0.5V - 4.5V)
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-5%
|
Target Gas
Carbon dioxide
|
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
12.0 Vdc
|
Dimension
65 x 50 x 20 mm
|
Humidity range
0-95% RH
0-99% RH
|
Working temperature
-20°C / +65°C
|
|||
|
CD-100 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Output
RS485
0-20 mA
4-20 mA
0-10 Vdc
2-12 Vdc
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Target Gas
Carbon dioxide
|
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
24 VAC
|
Dimension
123 x 70 x 43 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
-40°C / 40°C
|
|||
|
CD-200 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Output
RS485
0-20 mA
2-10 Vdc
4-20 mA
0-10 Vdc
Relay
|
Measurement range
0-2000 ppm
0-5000 ppm
0-10000 ppm
|
Target Gas
Carbon dioxide
|
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
24 VAC
|
Dimension
123 x 70 x 43 mm
|
Humidity range
0-99% RH
0-95% RH
|
Operating temperature
-10°C / +60°C
|
|||
|
CD-300 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
|
Target Gas
Carbon dioxide
|
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
|||
|
CD-300-D3 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Output
4-20 mA
0-10 Vdc
2-10 Vdc
0-20 mA
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Target Gas
Carbon dioxide
|
Accuracy
± 30ppm ± 5% of reading
|
Power Supply
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
|||
|
CD-400 Transmitter board with NDIR sensor for Carbon Dioxide (CO2) |
Output
4-20 mA
2-10 Vdc
0-10 Vdc
0-20 mA
Relay
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
|
Target Gas
Carbon dioxide
|
Accuracy
± 50ppm ± 5% of reading
|
Power Supply
24 VAC
24 VDC
|
Dimension
123 x 70 x 43 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-10°C / +60°C
|
|||
|
D-300 NDIR module for the measure of CO2 |
Output
I2C
UART
Analog (0.5V - 4.5V)
PWM
|
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Target Gas
Carbon dioxide
|
Accuracy
± 30ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|