| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Energetic consumption | Temperature range |
|---|---|---|---|---|---|---|---|---|---|
|
4NH3LL-100 3electrode electrochemical cell for ammonia detection. |
Life expectancy
About 2 years in air
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
<= 90 seconds
|
Output
30nA/ppm +/-20nA/ppm
|
|||
|
INFRA.sens® AK250TBH The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
<100 Vol.%
|
Target Gas
Multigas
|
Response Time
3 secondi (T90)
|
Output
RS232, Can, Analogica
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|