Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Energetic consumption | Temperature range |
|---|---|---|---|---|---|---|---|---|---|
|
3SH City Technology - 3 Electrode Electrochemical Cell for Sulfur dioxide |
Life expectancy
> 24 months
|
Measurement range
0 - 20 ppm
|
Target Gas
Sulphur dioxide
|
Response Time
< 15 seconds (T90)
|
Output
1.25 ± 0.25 μA/ppm
|
|||
|
4OX ECO LP City Technology - Electrochemical Cell for Oxygen |
Life expectancy
> 5 years
|
Measurement range
0-25% Oxygen
|
Target Gas
Oxygen
|
Response Time
< 15 seconds (T90)
|
Output
80 - 130 μA in air
|
|||
|
4OXV City Technology - Electrochemical Cell for Oxygen |
Life expectancy
> 24 months
|
Measurement range
1-25% vol. O2
|
Target Gas
Oxygen
|
Response Time
< 15 seconds (T90)
|
Output
100 ± 20 μA/ppm
|
|||
|
5OxLL City Technology - Electrochemical Cell for Oxygen |
Life expectancy
> 7 years
|
Measurement range
0-25% Oxygen
|
Target Gas
Oxygen
|
Response Time
< 15 seconds (T90)
|
Output
80 - 130 μA in air
|
|||
|
7NT City Technology - electrochemical cell for Nitric Oxide |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Nitric Oxide
|
Response Time
< 15 seconds (T90)
|
Output
550 ± 110 nA/ppm
|
|||
|
7SH City Technology - electrocheical cell for Sulfur Dioxide |
Life expectancy
> 24 months
|
Measurement range
0-20 ppm
|
Target Gas
Sulfur Dioxide
|
Response Time
< 15 seconds (T90)
|
Output
1.25 ± 0.25 μA/ppm
|
|||
|
INFRA.sens® AK2 SF6 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
<1 Vol.%
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analogic
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
|
|
Infra.Sens AK100 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
< 1 Vol.%
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
|
|
Infra.Sens AK250 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
< 2000ppm
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|
|
|
Infra.Sens AK5 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Measurement range
< 100 Vol.%
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Temperature range
5°C – 45°C
|