Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
4NH3LL-100 3electrode electrochemical cell for ammonia detection. |
Life expectancy
About 2 years in air
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
<= 90 seconds
|
Output
30nA/ppm +/-20nA/ppm
|
|||||
|
C4H10-S3-3V NDIR module for the measure of Butane. |
Measurement range
0-100% LEL
0-18000 ppm
|
Target Gas
Butano
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 2% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
GS+4NH3-100 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 40 seconds (T90)
|
Output
100 ± 30 nA/ppm
|
|||||
|
GS+4NH3-1000 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-1000 ppm
|
Target Gas
Ammonia
|
Response Time
< 60 seconds (T90)
|
Output
8 ± 4 nA/ppm
|
|||||
|
GS+4NH3-300 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-300 ppm
|
Target Gas
Ammonia
|
Response Time
< 40 seconds (T90)
|
Output
40 ± 15 nA/ppm
|
|||||
|
GS+7NH3-100 Electrochemical cell for ammonia. Ideally for industrial application, in particular for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 40 seconds (T90)
|
Output
115 ± 45 nA/ppm
|
|||||
|
GS+7NH3-1000 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-1000 ppm
|
Target Gas
Ammonia
|
Response Time
< 60 seconds (T90)
|
Output
8 ± 4 nA/ppm
|
|||||
|
NH3 3E 100 City Technology - 3 Electrode Electrochemical Cell for Ammonia with organic electrolyte |
Life expectancy
> 18 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 120 seconds (T90)
|
Output
90 ± 40 nA/ppm
|
|||||
|
NH3 3E 100 SE City Technology - 3 Electrode Electrochemical Cell for Ammonia |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 60 seconds (T90)
|
Output
130 ± 30 nA/ppm
|
|||||
|
NH3 3E 1000 City Technology - 3 Electrode Electrochemical Cell with organic electrolyte for Ammonia |
Life expectancy
> 18 months
|
Measurement range
0-1000 ppm
|
Target Gas
Ammonia
|
Response Time
< 120 seconds (T90)
|
Output
6 ± 3 nA/ppm
|