Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Application field | Heater consumption |
|---|---|---|---|---|---|---|---|---|
|
4NH3LL-100 3electrode electrochemical cell for ammonia detection. |
Life expectancy
About 2 years in air
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
<= 90 seconds
|
Output
30nA/ppm +/-20nA/ppm
|
||
|
GS+4NH3-100 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 40 seconds (T90)
|
Output
100 ± 30 nA/ppm
|
||
|
GS+4NH3-1000 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-1000 ppm
|
Target Gas
Ammonia
|
Response Time
< 60 seconds (T90)
|
Output
8 ± 4 nA/ppm
|
||
|
GS+4NH3-300 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-300 ppm
|
Target Gas
Ammonia
|
Response Time
< 40 seconds (T90)
|
Output
40 ± 15 nA/ppm
|
||
|
GS+7NH3-100 Electrochemical cell for ammonia. Ideally for industrial application, in particular for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 40 seconds (T90)
|
Output
115 ± 45 nA/ppm
|
||
|
GS+7NH3-1000 Electrochemical cell for ammonia. Great for fixed gas detectors. |
Life expectancy
> 24 months
|
Measurement range
0-1000 ppm
|
Target Gas
Ammonia
|
Response Time
< 60 seconds (T90)
|
Output
8 ± 4 nA/ppm
|
||
|
LPM2610-C13 The LPM2610 is a pre-calibrated module for LP gas alarms which is precisely calibrated in Figaro’s humidity and temperature controlled facility. The module uses TGS2610-C00. |
Target Gas
LPG
|
||||||
|
LPM2610-D09 The LPM2610 is a pre-calibrated module for LP gas alarms which is precisely calibrated in Figaro’s humidity and temperature controlled facility. |
Measurement range
500-10.000 ppm
|
Target Gas
LPG
|
Application field
Domestic
|
Heater consumption
56 mA
|
|||
|
NH3 3E 100 City Technology - 3 Electrode Electrochemical Cell for Ammonia with organic electrolyte |
Life expectancy
> 18 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 120 seconds (T90)
|
Output
90 ± 40 nA/ppm
|
||
|
NH3 3E 100 SE City Technology - 3 Electrode Electrochemical Cell for Ammonia |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Ammonia
|
Response Time
< 60 seconds (T90)
|
Output
130 ± 30 nA/ppm
|