Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
3NFF City Technology - Electrochemical Cell for Nitrogen Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-1000 ppm
|
Target Gas
Nitrogen monoxide
|
Response Time
< 25 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|||||
|
4NT City Technology - Electrochemical Cell for Nitrogen Monoxide |
Life expectancy
> 24 months
|
Measurement range
0 - 250 ppm
|
Target Gas
Nitrogen monoxide
|
Response Time
< 40 seconds (T90)
|
Output
400 ± 80 nA/ppm
|
|||||
|
D-300-3V NDIR module for the measure of CO2 |
Measurement range
0-2000 ppm
0-3000 ppm
0-5000 ppm
0-10000 ppm
0-2%
0-3%
0-5%
0-7%
0-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
UART
Analog (0.5V - 3.0V)
PWM
|
Accuracy
± 300ppm ± 3% of reading
± 30ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
EDI080120NG Guardian NG is a stand-alone analyzer for CO2, with infrared sensor technology. |
Measurement range
0-1000 ppm
|
Target Gas
Anidride Carbonica
|
Output
4-20 mA
0-20 mA
|
Power Supply
24V DC (18-30 V DC)
|
||||||
|
GS+4NO Electrochemical cell for nitroc oxide, ideal for portable and fixed gas detectors. |
Life expectancy
> 12 months
|
Measurement range
0 - 250 ppm
|
Target Gas
Nitrogen monoxide
|
Response Time
< 40 seconds (T90)
|
Output
400 ± 100 nA/ppm
|
|||||
|
GS+7NO Electrochemical cell for nitric oxide, ideal for fixed gas detector. |
Life expectancy
> 12 months
|
Measurement range
0-100 ppm
|
Target Gas
Nitrogen monoxide
|
Response Time
< 30 seconds (T90)
|
Output
550 ± 150 nA/ppm
|
|||||
|
NOXO-100 Electrochemical cell for measuring NO |
Measurement range
0-5000 ppm
|
Target Gas
Nitrogen monoxide
|
Response Time
< 7 seconds (T95)
|
Output
50 ± 10 nA/ppm
|
||||||
|
NX1 City Technology - Automotive Electrochemical Cell for Nitric oxide (NO) with inboard filter - BAR97 Approved |
Life expectancy
> 6 months
|
Measurement range
0-5000 ppm
|
Target Gas
Nitrogen monoxide
|
Response Time
< 8 seconds (T95)
|
Output
50 ± 10 nA/ppm
|
|||||
|
T-200 NDIR module for CO2 measurement |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
UART
Analogica (0.5V - 4.5V)
PWM
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
5.0 Vdc
|
Dimension
19.4 x 30 x10.3 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +60°C
|
||
|
T-200-3V NDIR module for CO2 measurement. |
Measurement range
400-2000 ppm
400-3000 ppm
400-5000 ppm
400-10000 ppm
0.04-2%
0.04-3%
0.04-5%
0.04-10%
|
Target Gas
Anidride Carbonica
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 50ppm ± 3% of reading
± 300ppm ± 3% of reading
|
Power Supply
3.3 Vdc
|
Dimension
19.4 x 30 x10.3 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +60°C
|