Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Accuracy | Power Supply | Dimension | Humidity range | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|
|
3H City Technology - Electrochemical Cell for Hydrogen Sulfide |
Life expectancy
> 24 months
|
Measurement range
0-200 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 35 seconds (T90)
|
Output
370 ± 70 nA/ppm
|
|||||
|
3HH City Technology - Electrochemical Cell for Hydrogen Sulfide |
Life expectancy
> 24 months
|
Measurement range
0-50 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
1.70 ± 0.30 μA/ppm
|
|||||
|
3HHLM City Technology - electrochemical cell for Hydrogen Sulfide |
Life expectancy
24 months
|
Measurement range
0-50 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
1.7 ± 0.3 μA/ppm
|
|||||
|
7H City Technology - Electrochemical cell for Hydrogen Sulfide |
Life expectancy
> 24 months
|
Measurement range
0-200 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 35 seconds (T90)
|
Output
370 ± 70 nA/ppm
|
|||||
|
7HH City Technology - Electrochemical Cell for Hydrogen Sulfide |
Life expectancy
> 24 months
|
Measurement range
0-50 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
1.7 ± 0.3 μA/ppm
|
|||||
|
7HHLM City Technology - Electrochemical Cell for Hydrogen Sulfide |
Life expectancy
> 12 months
|
Measurement range
0-50 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
1.7 ± 0.3 μA/ppm
|
|||||
|
7HLM City Technology - Electrochemical Cell for Hydrogen Sulfide |
Life expectancy
> 24 months
|
Measurement range
0-200 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 35 seconds (T90)
|
Output
370 ± 70 nA/ppm
|
|||||
|
C4H10-S3-3V NDIR module for the measure of Butane. |
Measurement range
0-100% LEL
0-18000 ppm
|
Target Gas
Butano
|
Output
I2C
PWM
UART
Analog (0.5V - 3.0V)
|
Accuracy
± 2% F.S.
|
Power Supply
3.3 Vdc
|
Dimension
33 x 33 x 13.1 mm
|
Humidity range
0-95% RH
0-99% RH
|
Operating temperature
-20°C / +50°C
|
||
|
GS+4DT Electrochemical cell for carbon monoxide and hydrogen sulfide, indicated for industrial application. |
Life expectancy
> 2 years in air
|
Measurement range
0-200 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
775 ± 275 nA/ppm
|
|||||
|
GS+4H2S DD Scientific - Electrochemical Cell for Hydrogen Sulphide |
Life expectancy
> 24 months
|
Measurement range
0-100 ppm
|
Target Gas
Hydrogen sulfide
|
Response Time
< 30 seconds (T90)
|
Output
700 ± 250 nA/ppm
|