| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output |
|---|---|---|---|---|---|---|
|
2EF City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 24 months
|
Measurement range
0-200 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 40 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|
2FO City Technology - Electrochemical Cell for Oxygen |
Life expectancy
> 24 months
|
Measurement range
0-25% Oxygen
|
Target Gas
Oxygen
|
Response Time
<10 seconds (T90)
|
Output
410 ± 70 μA/ppm
|
|
2FO-N City Technology - Electrochemical Cell for Oxygen |
Life expectancy
> 24 months
|
Measurement range
0-25% Oxygen
|
Target Gas
Oxygen
|
Response Time
<10 seconds (T95)
|
Output
410 ± 70 nA/ppm
|
|
3E City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-1000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 25 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|
3EF City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-1000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
100 ± 20 nA/ppm
|
|
3FD City Technology - Electrochemical cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-4000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
30 ± 6 nA/ppm
|
|
3M City Technology - 3 Electrode Electrochemical Cell for Carbon Monoxide (CO) |
Life expectancy
> 3 years
|
Measurement range
0-40.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
7 ± 2 nA/ppm
|
|
3MF City Technology - Electrochemical Cell for Carbon Monoxide |
Life expectancy
> 3 years
|
Measurement range
0-40.000 ppm
|
Target Gas
Carbon Monoxide
|
Response Time
< 30 seconds (T90)
|
Output
7 ± 2 nA/ppm
|
|
4OX ECO LP City Technology - Electrochemical Cell for Oxygen |
Life expectancy
> 5 years
|
Measurement range
0-25% Oxygen
|
Target Gas
Oxygen
|
Response Time
< 15 seconds (T90)
|
Output
80 - 130 μA in air
|
|
4OXV City Technology - Electrochemical Cell for Oxygen |
Life expectancy
> 24 months
|
Measurement range
1-25% vol. O2
|
Target Gas
Oxygen
|
Response Time
< 15 seconds (T90)
|
Output
100 ± 20 μA/ppm
|