| Product | Description | Accuracy | Energetic consumption | Measurement range | Temperature range | Target Gas | Response Time | Output | Output formats | Temp. drift | Application field | Heater consumption |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
INFRA.sens® AK2 SF6 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
<1 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analogic
|
||||
|
INFRA.sens® AK20 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
<1 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Output formats
RS232, Can, Analogica
|
Temp. drift
3 secondi (T90)
|
||||
|
INFRA.sens® AK250TBH The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
<100 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 secondi (T90)
|
Output
RS232, Can, Analogica
|
||||
|
Infra.Sens AK100 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
< 1 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
||||
|
Infra.Sens AK250 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
< 2000ppm
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
||||
|
Infra.Sens AK5 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
< 100 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
||||
|
Infra.Sens AK50 The INFRA.sens was specially developed for high-quality NDIR gas analysis. In the design phase, special emphasis was placed on high stability and a low detection limit. |
Accuracy
±2 % F.S.
|
Energetic consumption
< 10 Watt
|
Measurement range
< 20 Vol.%
|
Temperature range
5°C – 45°C
|
Target Gas
Multigas
|
Response Time
3 seconds (T90)
|
Output
RS232, Can, Analog
|
||||
|
LPM2610-C13 The LPM2610 is a pre-calibrated module for LP gas alarms which is precisely calibrated in Figaro’s humidity and temperature controlled facility. The module uses TGS2610-C00. |
Target Gas
LPG
|
||||||||||
|
LPM2610-D09 The LPM2610 is a pre-calibrated module for LP gas alarms which is precisely calibrated in Figaro’s humidity and temperature controlled facility. |
Measurement range
500-10.000 ppm
|
Target Gas
LPG
|
Application field
Domestic
|
Heater consumption
56 mA
|
|||||||
|
TGS2610-C00 TGS2610 is a semiconductor type gas sensor which combines very high sensitivity to LP gas with low power consumption and long life. |
Measurement range
500-10.000 ppm
|
Target Gas
LPG
Butane
|
Application field
Automotive
|
Heater consumption
280 mW
|