Gas sensors
Gas sensors
| Product | Description | Life expectancy | Measurement range | Target Gas | Response Time | Output | Power Supply |
|---|---|---|---|---|---|---|---|
|
C/N City Technology - Electrochemical Cell for Oxygen O2 |
Life expectancy
> 9 months
|
Measurement range
0-25% Oxygen
|
Target Gas
Oxygen
|
Response Time
< 20 seconds (T95)
|
Output
1.10 ± 0.17 mA in Air
|
|
|
C/Y City Technology - Electrochemical Cell for Oxygen for general purpose |
Life expectancy
> 12 months
|
Measurement range
0-25% Oxygen
|
Target Gas
Oxygen
|
Response Time
<10 seconds (T95)
|
Output
0.80 ± 0.12 mA in air
|
|
|
FCX-MEP2-F This board allows to measure the oxygen concentration in range 0.1-25%. |
Measurement range
0,1-25%
|
Target Gas
Oxygen
|
Output
4-20 mA not linear
|
Power Supply
12 +/- 3 VDC
|
||
|
FCX-MQ-F-AC This board allows to measure the oxygen concentration in range 0.05-1%. |
Measurement range
0,05-1%
|
Target Gas
Oxygen
|
Output
50-1000 mV not linear
|
Power Supply
5 +/- 0,2 VDC
|
||
|
FCX-MVL-F This board allows to measure the oxygen concentration in range 0.1-25% |
Measurement range
0,1-25%
|
Target Gas
Oxygen
|
Output
1-250 mV linear
|
Power Supply
5 +/- 0,2 VDC
|
||
|
FCX-MWL-F This board allows to measure the oxygen concentration in range 0.1-95% |
Measurement range
0,1-95%
|
Target Gas
Oxygen
|
Output
1-950 mV linear
|
Power Supply
5 +/- 0,2 VDC
|
||
|
KE-12 GS Oxygen Sensor KE Series are unique galvanic cell type oxygen sensors. |
Life expectancy
About 2.5 years
|
Measurement range
0-100%
|
Target Gas
Oxygen
|
Response Time
About 5 seconds
|
||
|
KE-25LF GS Oxygen Sensor KE-LF Series are unique lead-free galvanic cell type oxygen sensors with no influence by CO2. |
Life expectancy
About 5 years
|
Measurement range
0-30%
|
Target Gas
Oxygen
|
Response Time
About 15 seconds
|
||
|
KE-50 GS Oxygen Sensor KE Series are unique galvanic cell type oxygen sensors. |
Life expectancy
About 10 years
|
Measurement range
0-100%
|
Target Gas
Oxygen
|
Response Time
About 60 seconds
|
||
|
MOX-1 City Technology - Electrochemical Cell for Oxygen O2 |
Life expectancy
1.5 x 106 % O2 hours at 20°C
|
Measurement range
0-1500 mBar O2
|
Target Gas
Oxygen
|
Response Time
< 15 seconds (T90)
|
Output
9 - 13 mV in 210 mBar O2
|